Error Messages For Torqeedo Power Batteries - Torqeedo Cruise 3.0 R Originalbetriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Display
Cause
E05
Motor/propeller blocked
E06
Voltage at motor too low
E07
Overcurrent at the motor
E08
Circuit board
overtemperature
E21
Faulty calibration of
tiller / remote throttle
E22
Magnetic sensor
defective
E23
Value range wrong
E30
Motor communication
error; error in the power
supply to the motor
E32
Tiller communication
error / remote throttle
E33
General communication
error
E34
Emergency kill switch or
kill switch actuated
E43
Battery empty
Other error codes
Defect
No indication in
No voltage or defective
the display
Troubleshooting
Set the main switch to the "OFF"
position. Release the blockage and turn
the propeller one turn further by hand.
Reconnect the motor cable.
Low battery state of charge. If necessary,
the motor can be driven slowly from the
stop position.
Continue driving with low power. Contact
Torqeedo Service.
After a short waiting time (approx. 10
minutes), the motor can be operated
slowly. Contact Torqeedo Service.
Set forwards/reverse motion
Set forwards/reverse motion
Set forwards/reverse motion
Contact Torqeedo Service;
Check that the main switch is in the "ON"
position.
Check the plug connections of the data
cables and cables.
Check the plug connections and the
cables. Switch the motor off and on again.
Make sure that the cause of the error has
been eliminated, set the emergency kill
switch or the kill switch to the position for
normal operation and restart the system.
Charge the battery. If necessary, the
motor can be driven slowly from the stop
position.
Contact Torqeedo Service.
Check power source, main fuse and
main switch. If the power supply is okay:
Contact Torqeedo Service.
Display
Cause
Motor cannot be
Trim rod bent
tilted; tilt lock lever
cannot be moved

11.2 Error messages for Torqeedo power batteries

Display
Cause
E70
Over/under temperature
during charging
E71
Over/under temperature
during discharge
E72
Overtemperature battery
FET
E73
Overcurrent during
discharge
E74
Overcurrent during
charging
E75
Activating the
Pyroswitch
E76
Battery undervoltage
E77
Overvoltage during
charging
E78
Battery overcharge
E79
Battery electronic fault
E80
Deep discharging
DE
EN
Troubleshooting
Check trim rods, replace if necessary.
Troubleshooting
Remove the reason the temperature has
gone out of range. If necessary, remove
the charger unit to cool down. Switch the
battery off and on.
Remove the reason the temperature has
gone out of range. If necessary, do not
use the battery temporarily to allow it to
cool down. Switch the battery off and on.
Let the battery cool down. Switch the
battery off and on.
Remove cause of overcurrent. Switch the
battery off and on.
Remove the charger unit. Only use a
Torqeedo charger unit. Switch the battery
off and on.
Contact Torqeedo Service.
Charge the battery.
Remove the charger unit. Only use a
Torqeedo charger unit. Switch the battery
off and on.
Remove the charger unit. Only use a
Torqeedo charger unit. Switch the battery
off and on.
Contact Torqeedo Service.
Contact Torqeedo Service.