Spezifikationen
show
portsensor {port_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
radius
radius {PRIMARY=0|SECONDARY=1} enabled set
<off=0/on=1>
radius {PRIMARY=0|SECONDARY=1} enabled
show
radius {PRIMARY=0|SECONDARY=1} server set
"<dns_name>"
radius {PRIMARY=0|SECONDARY=1} server
show
radius {PRIMARY=0|SECONDARY=1} passw ord
set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} passw ord
hash set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} auth timeout
set {num_secs}
radius {PRIMARY=0|SECONDARY=1} auth timeout
show
radius {PRIMARY=0|SECONDARY=1} retries set
{0..99}
radius {PRIMARY=0|SECONDARY=1} retries
show
radius chap enabled set <off=0/on=1>
radius chap enabled show
radius message auth set <off=0/on=1>
radius message auth show
radius default timeout set {num_secs}
radius default timeout show
snmp
snmp port set {ip_port}
snmp port show
snmp snmpget enabled set {OFF=0|ON=1}
snmp snmpget enabled show
snmp snmpset enabled set {OFF=0|ON=1}
snmp snmpset enabled show
snmp snmpv2 enabled set {OFF=0|ON=1}
snmp snmpv2 enabled show
snmp snmpv2 public set "{text}"
snmp snmpv2 public show
snmp snmpv2 private set "{text}"
snmp snmpv2 private show
snmp system {CONTACT=0|NAME=1|
LOCATION=2} set "{text}"
snmp system {CONTACT=0|NAME=1|
LOCATION=2} show
snmp snmpv3 enabled set {OFF=0|ON=1}
snmp snmpv3 enabled show
snmp snmpv3 username set "{text}"
snmp snmpv3 username show
snmp snmpv3 authalg set {NONE=0|MD5=1|
SHA1=2|SHA256=3|SHA384=4|SHA512=5}
snmp snmpv3 authalg show
snmp snmpv3 privalg set {NONE=0|DES=1|
3DES=2|AES128=3|AES192=4|AES256=5|
AES192*=6|AES256*=7}
snmp snmpv3 privalg show
snmp snmpv3 authpassw d set "{passw d}"
snmp snmpv3 privpassw d set "{passw d}"
Expert Power Control 8316
LEGACY - show s state for sensor values action
enters cmd group "radius"
enables radius client
show if radius client enabled
sets radius server address
show s radius server address
sets radius server shared secret
sets radius server crypted shared secret
sets server request timeout
show s server request timeout
sets server number of retries
show s server number of retries
enables CHAP
show s if CHAP is enabled
enables request message authentication
show s if request message authentication is
enabled
sets default session timeout (w hen not returned
as Session-Timout Attribute)
show s default session timeout
enters cmd group "snmp"
sets SNMP UDP port
show s SNMP UDP port
enables SNMP GET cmds on/off
show if SNMP GET cmds are enabled
enables SNMP SET cmds on/off
show if SNMP SET cmds are enabled
enables SNMP v2 on/off
show if SNMP v2 is enabled
enables SNMP v3 on/off
show if SNMP v3 isenabled
sets SNMP v2 public cummnity
show s SNMP v2 public community
sets sysLocation/sysName/sysContact
gets sysLocation/sysName/sysContact
sets SNMP v2 private community
show s SNMP v2 private community
sets SNMP v3 username
show s SNMP v3 username
sets SNMP v3 authentication
show SNMP v3 authentication algorithm
sets SNMP v3 privacy algorithm
show SNMP v3 privacy algorithm
sets SNMP v3 authentication passw ord
sets SNMP v3 privacy passw ord
L
90
© 2022 GUDE Systems GmbH