"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
extsensor {port_num} {sen_type} {sen_field}
events type show
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
extsensor {port_num} {sen_type} {sen_field}
maxval show
extsensor {port_num} {sen_type} {sen_field}
minval set {num}
extsensor {port_num} {sen_type} {sen_field}
minval show
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
extsensor {port_num} {sen_type} {sen_field} hyst
show
extsensor {port_num} {sen_type} {sen_field}
publish mode set {NONE=0|INTERVAL=1|
DELTA=2|INTERV_DELTA=3}
extsensor {port_num} {sen_type} {sen_field}
publish mode show
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain set {OFF=0|ON=1}
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain show
extsensor {port_num} {sen_type} {sen_field}
publish timer set {num_secs}
extsensor {port_num} {sen_type} {sen_field}
publish timer show
extsensor {port_num} {sen_type} {sen_field}
publish delta set {float}
extsensor {port_num} {sen_type} {sen_field}
publish delta show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
http
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=22|HTTPS_REDIR=3}
http server show
http port set {ip_port}
http port show
http portssl set {ip_port}
http portssl show
http tls mode set {TLS12=0|TLS13_12=1|TLS13=2|
TLS13_12_11=3}
http tls mode show
http ajax enabled set {OFF=0|ON=1}
http ajax enabled show
Expert Power Control 8316
show s w hat event types are enabled
sets maximum value for sensor
show s maximum value for sensor
sets minimum value for sensor
show s minimum value for sensor
sets hysterese value for sensor
show s hysterese value for sensor
sets publish mode
show s publish mode
sets mqtt retain
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
sets Port for Pow er Port Sw itching actions
show s Port for Pow er Port Sw itching actions
sets Port state for Pow er Port Sw itching actions
show s Port state for Pow er Port Sw itching
actions
sets sensor Min/Max measurement period
show s sensor Min/Max measurement period
enters cmd group "http"
sets accepted connection types
show s accepted connection types
sets http port
show s http port
sets https port
show s https port
restricts TLS mode
show s TLS mode restriction
enables ajax autorefresh on/off
show s if ajax autorefresh enabled
6
6
6
6
6
6
6
6
6
6
6