ELECTRICAL CONNECTIONS

WARNING: insert the
(optional) receiver as
shown in the figure.
Incorrect insertion can
seriously damage the
receiver.
8 9 10 11 12 13 14
M1 M2
1
ANT - Antenna
2
COM - Common (-)
3
SUN ON/OFF - N.A. input for deactivating the sun sensor
• entry closed = sensor disabled
• entry open = sensor enabled
4
C1 - Motor 1 open
5
C2 - Motor 1 close
6
C3 - Motor 2 open
7
C4 - Motor 2 close
8
SENSOR INPUT - WIND / MISTRAL / METEO / HURRICANE
sensor input
5
+
4
3
2
DIP
-
1
WIND
SUN
1 2
RAIN
SENS
TEMP
MOT
1 2 3 4 5 6 7
N
L
METEO / HURRICANE
L
N
WARNING: the operation of these
inputs depends on the operational
logic set. See the paragraph on
OPERATIONAL LOGIC
- 18 -
8 9 10 11 12 13 14
M1 M2
8 9 10 11 12 13 14
M1 M2
9
Motor 1 open
10
Motor 1 common
11
Motor 1 close
12
Motor 2 open
13
Motor 2 common
14
Motor 2 close
N
Neutral supply
L
Phase supply
m
WARNING: if the motors are synchronised,
invert the motor 2 open and close cables.
F = 5A
15
16
N
L
N
L
WIND / MISTRAL