LED Frequency
Sets the LED PWM
frequency
Pan/Tilt
Configures the device
head
B.O. Moving
Automatic blackout when
head moves
Fan
Fan control

Dimmer curves

Linear
DMX value

SERVICE MENU

Starting from the main display, press ENTER to go to the main menu. Use the UP and DOWN control keys to select the Service menu and
press ENTER.
This will take you to the submenu for adjusting the submenu options (select via UP and DOWN, confirm via ENTER, change value via LEFT
and RIGHT, confirm via ENTER).
Calibrate—Calibrate the components with values of 000 to 255 (Password 050).
Test Manual—Manually test the components with values of 000 to 255.
Reset Motor—Reset the motors. All = All motors, Pan&Tilt = Pan and tilt motors, Head Only = Motors in device head.
12
650 Hz, 1530 Hz,
3600 Hz, 12 KHz,
25 KHz
Pan Reverse
Tilt Reverse
Pan Angle
Feedback
OFF
ON
Head Fan
Base Fan
Exponential
Logarithmic
DMX value
DMX value
OFF
Pan movement direction does not reverse
ON
Pan movement direction reverses
OFF
Tilt movement direction does not reverse
ON
Tilt movement direction reverses
630
Pan angle 630°
540
Pan angle 540°
OFF
Automatic position correction deactivated
ON
Automatic position correction activated
No blackout when head moves
Blackout when head moves
Auto
The fan speed will adjust automatically to the
temperature of the device head
Low
Consistently low fan speed with
reduced brightness, as required
Auto
The fan speed will adjust automatically to the
temperature of the device base
Low
Consistently low fan speed with
reduced brightness, as required
S-curve
DMX value