Herunterladen Inhalt Inhalt Diese Seite drucken

Dimmer Curves - Cameo AURO SPOT Bedienungsanleitung

Led moving head
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
J. DEVICE SETTINGS (Settings)
Pressing the MODE button will take you to the selection menu for system settings. Using the arrow buttons, select the menu item "Settings" (dark
background) and confirm by pressing ENTER. You will then be taken to the sub-menu to set the following sub-menu items:
System Settings
DMX Address
001
Mode
DMX 22CH
Settings
System Info
Settings
Display Rev
=
Flip Display
Display
=
Display lighting
DMX Fail
=
Operation status with DMX signal interruption
DimmerCurve
=
Dimmer Curve
Pan Rev
=
Pan Reverse
Tilt Rev
=
Tilt Reverse
Pan Angle
=
Pan Angle
Feedback
=
position correction
Fan Set
=
Fan Speed
Mov Blackout
=
Automatic blackout during head movement
Test
=
Function test
Reset
=
Reset

DIMMER CURVES

linear
DMX value
Confirm the setting changes with ENTER and press the MODE button (possibly several times) to return to the main display.
exponential
logarithmic
DMX value
DMX value
ON
= Rotation of the display by 180° (overhead installation)
OFF
= no rotation of the display
ON
= permanently on
OFF
= deactivation after approx. 90 seconds of inactivity
Hold
= last command is held
Auto
= activates the AUTO mode
Sound
= activates the Music control mode
Blackout
= activates Blackout
Linear
= The light intensity increases linearly with the DMX value.
Exp
= Adjustment of the light intensity is finer in the lower DMX
value range and coarser in the upper DMX value range.
Log
= Adjustment of the light intensity is coarser in the lower DMX
value range and finer in the upper DMX value range.
S-Curve
= Adjustment of the light intensity is finer in the lower and
upper DMX value ranges and coarser in the middle DMX value
range.
ON
= Reversal of the Pan direction
OFF
= no reversal of the Pan direction
ON
= Reversal of the Tilt direction
OFF
= no reversal of the Tilt direction
630
= Pan angle 630°
540
= Pan angle 540°
ON
= activates automatic position correction
OFF
= deactivates automatic position correction
Regular
= maximum brightness at normal fan function
Silent
= if necessary, reduced brightness with silent fan
ON
= Blackout during head movement
OFF
= no blackout during head movement
ON
= step-by-step function test of LED and all motors (Pan, Tilt,
Gobo...)
OFF
= stops the function test
Pan&Tilt
= Resetting of the Pan & Tilt motors
= Resetting all Head motors (colour wheel, gobo wheel,
Head
prism...)
All
= Resetting all motors and settings
S-curve
DMX value
19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Auro spot 200Clas100Clas200

Inhaltsverzeichnis