1. Do not put the spanner on the cap or cover.
The valve may be broken.
2. If applying excessive torque, the nut may
be broken according to some installation
conditions.
• After the installation work, be sure to check gas
leak of connecting part of the pipes with nitrogen.
Refrigerant Pipe Length
Single
Allowable pipe
length (m)
Total length
Simultaneous twin
Allowable pipe length (m)
Total
length
+
1
+
1
Maximum
50
13-EN
CAUTION
NO GOOD
Cap
Height difference (Indoor-outdoor H) (m) Pipe diameter (mm)
L
Indoor unit: Upper
75
30
Distributed
Distributed
pipes
pipes
2
2
3
2
Maximum
3
3
Maximum
15
10
Figure of Single
Indoor Unit
Outdoor unit
• Pressure of R410A is higher than that of R22
(Approx. 1.6 times).
Therefore, using a torque wrench, tighten the
flare pipe connecting sections which connect
the indoor/outdoor units at the specified
tightening torque.
Incomplete connections may cause not only a
gas leak, but also a trouble of the refrigeration
cycle.
Do not apply refrigerating machine oil to the
flared surface.
Cover
Outdoor unit: Lower Gas side
30
Height difference (m)
Indoor-outdoor H Indoor-
indoor
Indoor
Outdoor
(Δh)
unit:
unit:
Upper
Upper
30
30
0.5
Figure of Simultaneous twin
Outdoor unit
– 13 –
Outdoor Unit Installation Manual
Liquid side
Ø15.9
Ø9.5
Pipe diameter (mm)
Main pipe
Branching pipe
Gas side Liquid
Gas side Liquid
side
Ø15.9
Ø9.5
Ø15.9
Indoor Unit
Indoor Unit
Distributor
2
3
1
Number of bent
portions
10 or less
Number of
bent portions
side
Ø9.5
10 or less