Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; General Notes; General Information - EOS Goliath Serie Montage- Und Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dear customer,
You have purchased a high-quality technical
device with which you will have years of sauna
fun. This sauna heater was designed and inspect-
ed according to the current European safety
standards and manufactured at the factory
in accordance with the quality management
standard DIN EN ISO 9001:2015.
This detailed installation and operation manual
has been prepared for your information. Please
in particular thoroughly read the important
notes and the information on electrical con-
nection.
We wish you exhilarating recreational experience
and lots of fun with your sauna!

Intended use

This sauna heater is exclusively intended for the
heating of sauna cabins in private or commer-
cial use (public sauna), in combination with an
appropriate control unit.
Any other use over and above the intended
purpose is not considered as appropriate use!
Compliance of the standard operation, mainte-
nance and repair conditions is also an element
of appropriate use.
The manufacturer cannot be held liable for
deviating, unauthorized alterations and any re-
sulting damages: the initiator of these changes
bears the full risk.

General information

Please check whether the unit has arrived in per-
fect condition. Any transport damages should be
immediately reported to the freight forwarder
delivering the goods or you should contact the
company that shipped the goods.
Please note that you will only be able to achieve
an optimum sauna climate if the cabin with its air
intake and ventilation, the sauna heater and the
control unit are aligned to each other.
Please observe the information and stipulations
made by your sauna supplier.
Sauna heaters heat up your sauna cabin using
heated convective air. Here, fresh air is drawn
in from the air intake which, when heated, rises
upwards (convection) and is then circulated
within the cabin. Part of the used air is pushed
out through the vent in the cabin. This creates a
typical sauna climate which can achieve temper-
atures of approx. 110°C measured directly under
the ceiling of your sauna, dropping in temper-
ature to approx. 30-40°C towards the floor. It is
therefore not unusual to measure temperatures
of 110°C on the temperature sensor hanging
over the heater, whilst the thermometer hanging
on the sauna wall, approx. 20-25 cm under the
cabin ceiling, only indicates 85°C. The bathing
temperature generally lies between 80°C and
90°C in the area of the upper bench when the
temperature is set to maximum.
Please note that the highest temperatures are
always generated over the sauna heater and that
the temperature sensor and the safety limiter
must be mounted there in accordance with the
control unit installation instructions.
When heating up for the first time, you may
notice a slight smell caused by evaporating
lubricants used in production processes. Please
ventilate your cabin before beginning your
sauna bath.
EN
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Goliath 18Goliath 24Goliath 30Goliath 36

Inhaltsverzeichnis