Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 227

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Prowirl R 200 FOUNDATION Fieldbus
Rela-
tive
Index
21
TRDSRVSB_VTX_DSCTemperaturePT1_1
22
TRDSRVSB_VTX_DSCTemperaturePT2_1
23
TRDSRVSB_VTX_GapCapacity_1
24
TRDSRVSB_VTX_GapCapacityDelta_1
25
TRDSRVSB_Dev_CalTimeMinute_1
26
TRDSRVSB_Dev_CalTimeHour_1
27
TRDSRVSB_Dev_CalTimeDay_1
28
TRDSRVSB_Dev_CalTimeMonth_1
29
TRDSRVSB_Dev_CalTimeYear_1
30
TRDSRVSB_Dev_CalHistoryCounter_1
31
TRDSRVSB_Dev_MapCalFactor_1
32
TRDSRVSB_Dev_CalTimeString_1
33
TRDSRVSB_Dev_CalHistoryEntryNum_1
34
TRDSRVSB_Dev_CalTimeSelectedEntry_1
35
TRDSRVSB_Dev_CalFactorSelectedEntry_1
36
TRDSRVSB_Dev_ConfirmCalibration_1
37
TRDSRVSB_Dev_CalTimeAmPm_1
38
TRDSRVSB_Dev_CalHiLimitDays_1
39
TRDSRVSB_Dev_CalLoLimitHours_1
40
TRDSRVSB_Dev_CalHiLimitHours_1
41
TRDSRVSB_VTX_CalibrationFactor_1
42
TRDSRVSB_VTX_DSCAdjustment_1
43
TRDSRVSB_VTX_DSPMode_1
44
TRDSRVSB_VTX_FrequencyReferenceDrift_1
45
TRDSRVSB_VTX_InnerDiameter_1
46
TRDSRVSB_VTX_Kurtosis_1
47
TRDSRVSB_VTX_MaxVortexFrequencyGas_1
48
TRDSRVSB_VTX_MaxVortexFrequencyLiquid_1
49
TRDSRVSB_VTX_MeterBodyProperties_1
50
TRDSRVSB_VTX_MinVortexFrequencyGas_1
51
TRDSRVSB_VTX_MinVortexFrequencyLiquid_1 Min. vortex frequency
52
TRDSRVSB_VTX_OverallRefCapacity_1
53
TRDSRVSB_VTX_ProcessResonanceFreq_1
54
TRDSRVSB_VTX_SensorDiameter_1
55
TRDSRVSB_VTX_TemperatureCalcMode_1
Endress+Hauser
Name
Calibration counter
Calibration date/time
Select calibration log
Sensor adjustment
Reference frequency
Tube inner diameter
Meter body properties
Min. vortex frequency
Resonance frequency
Label
Data type
DSC sensor
FLOAT
temperature PT1
DSC sensor
FLOAT
temperature PT2
Gap capacity
FLOAT
Gap capacity
FLOAT
difference
Minute
UINT8
Hour
UINT8
Day
UINT8
Month
ENUM16
Year
UINT8
UINT32
Calibration factor
FLOAT
STRING
UINT8
entry
Timestamp
STRING
Calibration factor
FLOAT
Confirm settings
ENUM16
AM/PM
ENUM16
UINT8
UINT8
UINT8
Calibration factor
FLOAT
ENUM16
DSP mode
BIT_ENUM32
FLOAT
drift
FLOAT
Vortex kurtosis
FLOAT
Max. vortex
FLOAT
frequency gas
Max. vortex
FLOAT
frequency liquid
STRING
FLOAT
gas
FLOAT
liquid
Overall reference
FLOAT
capacity
FLOAT
Sensor diameter
FLOAT
Temperature
ENUM16
calculation mode
Storage
Size
MODE_BLK
Class
(Bytes)
Static
4
Static
4
Static
4
Dynamic
4
Static
1
AUTO
Static
1
AUTO
Static
1
AUTO
Static
2
AUTO
Static
1
AUTO
Static
4
AUTO
Static
4
AUTO
Static
20
AUTO
Static
1
AUTO
Static
20
Static
4
Static
2
AUTO
Static
2
AUTO
Static
1
Static
1
Static
1
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
Static
4
AUTO
Static
4
Static
4
AUTO
Static
4
AUTO
Static
32
AUTO
Static
4
AUTO
Static
4
AUTO
Dynamic
4
Dynamic
4
Static
4
AUTO
Static
2
AUTO
Anhang
Wri-
tabi-
lity
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
227