Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 197

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Prowirl R 200 FOUNDATION Fieldbus
Rela-
Name
tive
Index
21
TRDEXPIN_VTX_SteamQualitySelector_1
22
TRDEXPIN_VTX_FluidSelectorSteam_1
23
TRDEXPIN_VTX_MediumSelector_1
24
TRDEXPIN_VTX_FluidSelectorGas_1
25
TRDEXPIN_VTX_FluidSelectorLiquid_1
26
TRDEXPIN_VTX_LimitReynoldsnumber_1
27
TRDEXPIN_VTX_SensorEmergencyMode_1
28
TRDEXPIN_VTX_SteamQualityLimit_1
29
TRDEXPIN_VTX_ElectronicsTemperature_1
30
TRDEXPIN_SU_Temperature_1
31
TRDEXPIN_VTX_Voltages_1
35
TRDEXPIN_SPV_PowerOnCounter_1
TRDEXPIN_View1
TRDEXPIN_StRev
TRDEXPIN_BlockErr
TRDEXPIN_TransducerType
TRDEXPIN_XdError
TRDEXPIN_BlockErrDesc_1
STD_LockingState
TRDEXPIN_View2
TRDEXPIN_StRev
TRDEXPIN_TransducerType
STD_UserLevel
STD_LicenseCode
STD_SWOptionActiveOverview
STD_GeniXMLBuildNumber
VTX_EmergencyModeValidity
VTX_SteamQualitySelector
VTX_FluidSelectorSteam
VTX_MediumSelector
VTX_FluidSelectorGas
VTX_FluidSelectorLiquid
VTX_LimitReynoldsnumber
VTX_SensorEmergencyMode
VTX_SteamQualityLimit
SU_Temperature
SPV_PowerOnCounter
TRDEXPIN_View3
TRDEXPIN_StRev
TRDEXPIN_BlockErr
Endress+Hauser
Label
Data type
Steam quality
ENUM16
Select steam type
ENUM16
Select medium
ENUM16
Select gas type
ENUM16
Select liquid type
ENUM16
Reynolds number limit
FLOAT
Activate sensor
ENUM16
emergency mode
Steam quality limit
FLOAT
Electronic temperature
FLOAT
Temperature unit
ENUM16
Measured voltage 0
FLOAT
Power on
UINT32
View -1-
VIEW1
Static Revision
UINT16
Block Error
BIT_ENUM16
Transducer Type
ENUM16
Transducer Error
ENUM8
Block error description BIT_ENUM32
Locking status
BIT_ENUM16
View -2-
VIEW2
Static Revision
UINT16
Transducer Type
ENUM16
Access status tooling
ENUM16
Activate SW option
UINT32
Software option
BIT_ENUM32
overview
XML build number
UINT32
ENUM16
Steam quality
ENUM16
Select steam type
ENUM16
Select medium
ENUM16
Select gas type
ENUM16
Select liquid type
ENUM16
Reynolds number limit
FLOAT
Activate sensor
ENUM16
emergency mode
Steam quality limit
FLOAT
Temperature unit
ENUM16
Power on
UINT32
View -3-
VIEW3
Static Revision
UINT16
Block Error
BIT_ENUM16
Storage
Size (Bytes) MODE_BLK Writa-
Class
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Dynamic
4
AUTO
Static
2
AUTO
Static
4
Static
4
AUTO
Dynamic
17
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Static
46
Static
2
Static
2
Static
2
Static
4
AUTO
Static
4
Static
4
Static
2
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Dynamic
21
Static
2
Dynamic
2
Anhang
bility
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
197