Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 173

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Prowirl R 200 FOUNDATION Fieldbus
Rela-
tive
Index
11
TRDASUP_TransducerTypeVer
12
TRDASUP_XdError
13
TRDASUP_CollectionDirectory
14
TRDASUP_BlockErrDesc_1
15
TRDASUP_STD_UserLevel_1
16
TRDASUP_STD_LockingState_1
17
TRDASUP_STD_SWOptionActiveOverview_1
18
TRDASUP_VTX_AmbientPressure_1
19
TRDASUP_VTX_CalorificValueType_1
20
TRDASUP_VTX_DeltaHeatCalculation_1
21
TRDASUP_VTX_EnthalpyType_1
22
TRDASUP_VTX_ExpansionCoeff_1
23
TRDASUP_VTX_ExternalInputSelector_1
24
TRDASUP_VTX_Fix2ndFluidTemperature_1
25
TRDASUP_VTX_FixCalorificValue_1
26
TRDASUP_VTX_FixDensity_1
27
TRDASUP_VTX_FixFluidTemperature_1
28
TRDASUP_VTX_FixPressure_1
29
TRDASUP_VTX_FixSteamQuality_1
30
TRDASUP_VTX_FixViscosityGas_1
31
TRDASUP_SU_DynamicViscosity_1
32
TRDASUP_VTX_FixViscosityLiquid_1
33
TRDASUP_VTX_FixZFactor_1
34
TRDASUP_VTX_GasMixture_1
35
TRDASUP_VTX_InletConfig_1
36
TRDASUP_VTX_InletLength_1
37
TRDASUP_VTX_InstallationFactor_1
38
TRDASUP_VTX_MatingPipeDiameter_1
39
TRDASUP_SU_Length_1
40
TRDASUP_VTX_MolPercentAr_1
41
TRDASUP_VTX_MolPercentC2H3Cl_1
42
TRDASUP_VTX_MolPercentC2H4_1
43
TRDASUP_VTX_MolPercentC2H6_1
44
TRDASUP_VTX_MolPercentC3H8_1
Endress+Hauser
17.1.2
Transducer Block Advanced Setup
Name
Label
Data type
UINT16
Transducer Error
ENUM8
Collection Directory
UINT32
Block error
BIT_ENUM32
description
Access status
ENUM16
tooling
Locking status
BIT_ENUM16
Software option
BIT_ENUM32
overview
Atmospheric
FLOAT
pressure
Calorific value type
ENUM16
Delta heat
ENUM16
calculation
Enthalpy type
ENUM16
Linear expansion
FLOAT
coefficient
External value
ENUM16
2nd temperature
FLOAT
delta heat
Calorific value
FLOAT
Fixed density
FLOAT
Fixed temperature
FLOAT
Fixed process
FLOAT
pressure
Steam quality value
FLOAT
Dynamic viscosity
FLOAT
Dynamic viscosity
ENUM16
unit
Dynamic viscosity
FLOAT
Z-factor
FLOAT
Gas mixture
BIT_ENUM32
Inlet configuration
ENUM16
Inlet run
FLOAT
Installation factor
FLOAT
Mating pipe
FLOAT
diameter
Length unit
ENUM16
Mol% Ar
FLOAT
Mol% C2H3Cl
FLOAT
Mol% C2H4
FLOAT
Mol% C2H6
FLOAT
Mol% C3H8
FLOAT
Storage
Size
MODE_BLK Writa-
Class
(Bytes)
Static
2
Dynamic
1
Static
4
Dynamic
4
Static
2
Dynamic
2
Static
4
Static
4
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Anhang
bility
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
173

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis