Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 182

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Anhang
Relative
Index
51
TRDDIAG_MassFlowCondensateInput
TRDDIAG_Out8Status
FLOW_Out8Value
52
TRDDIAG_OverallMassFlowInput
TRDDIAG_Out7Status
FLOW_Out7Value
53
TRDDIAG_SU_MassFlow_1
54
TRDDIAG_FlowVelocityInput
TRDDIAG_Out12Status
FLOW_Out12Value
55
TRDDIAG_SU_Velocity_1
56
TRDDIAG_VolumeFlowInput
TRDDIAG_Out1Status
FLOW_Out1Value
57
TRDDIAG_SU_VolumeFlow_1
58
TRDDIAG_CorrVolumeFlowInput
TRDDIAG_Out3Status
FLOW_Out3Value
59
TRDDIAG_SU_CorrVolumeFlow_1
60
TRDDIAG_TemperatureInput
TRDDIAG_Out4Status
FLOW_Out4Value
61
TRDDIAG_SU_Temperature_1
62
TRDDIAG_CalcSaturatedSteamPressureInput
TRDDIAG_Out5Status
FLOW_Out5Value
63
TRDDIAG_SU_Pressure_1
64
TRDDIAG_SteamQualityInput
TRDDIAG_Out6Status
FLOW_Out6Value
65
TRDDIAG_EnergyFlowInput
TRDDIAG_Out9Status
FLOW_Out9Value
66
TRDDIAG_HeatFlowDifferenceInput
TRDDIAG_Out10Status
FLOW_Out10Value
67
TRDDIAG_SU_EnergyFlow_1
68
TRDDIAG_ReynoldsNumberInput
TRDDIAG_Out11Status
FLOW_Out11Value
182
Name
Condensate mass flow
Condensate mass flow
Corrected volume flow
Corrected volume flow
Corrected volume flow
Temperature unit
Calculated saturated
Calculated saturated
Heat flow difference
Heat flow difference
Label
Data type
Standard
Status
ENUM8
FLOAT
Total mass flow
Standard
Status
ENUM8
Total mass flow
FLOAT
Mass flow unit
ENUM16
Flow velocity
Standard
Status
ENUM8
Flow velocity
FLOAT
Velocity unit
ENUM16
Volume flow
Standard
Status
ENUM8
Volume flow
FLOAT
Volume flow unit
ENUM16
Standard
Status
ENUM8
FLOAT
ENUM16
unit
Temperature
Standard
Status
ENUM8
Temperature
FLOAT
ENUM16
Standard
steam pressure
Status
ENUM8
FLOAT
steam pressure
Pressure unit
ENUM16
Steam quality
Standard
Status
ENUM8
Steam quality
FLOAT
Energy flow
Standard
Status
ENUM8
Energy flow
FLOAT
Standard
Status
ENUM8
FLOAT
Energy flow unit
ENUM16
Reynolds number
Standard
Status
ENUM8
Reynolds number
FLOAT
Proline Prowirl R 200 FOUNDATION Fieldbus
Storage
Size
Class
(Bytes)
Dynamic
5
Dynamic
1
Dynamic
4
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
Dynamic
5
Dynamic
1
Dynamic
4
Dynamic
5
Dynamic
1
Dynamic
4
Static
2
Dynamic
5
Dynamic
1
Dynamic
4
MODE_BLK
Wri-
tabi-
lity
AUTO
X
AUTO
X
AUTO
X
AUTO
X
AUTO
X
AUTO
X
AUTO
X
Endress+Hauser

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis