Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 200

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Anhang
Rela-
tive
Index
TRDHBT_StRev
TRDHBT_Strategy
TRDHBT_AlertKey
TRDHBT_TransducerType
HBT_ExternalDeviceInfo
Dev_CustomerName
Dev_PlantSection
Rela-
tive
Index
11
TRDHBTR1_TransducerTypeVer
12
TRDHBTR1_XdError
13
TRDHBTR1_CollectionDirectory
14
TRDHBTR1_BlockErrDesc_1
15
TRDHBTR1_HBTR_VerificationDateTime_1
16
TRDHBTR1_HBTR_VerificationCounter_1
17
TRDHBTR1_HBTR_OperationHours_1
18
TRDHBTR1_HBTR_VerificationOverallResult_1
19
TRDHBTR1_HBTR_VerificationSensorResult_1
20
TRDHBTR1_HBTR_VerificationSensElectronicResult_1
21
TRDHBTR1_HBTR_VerificationInputOutputResult_1
22
TRDHBTR1_HBTR_VerificationSupplyVoltageResult_1
23
TRDHBTR1_HBTR_ExternalDeviceInfo_1
24
TRDHBTR1_HBTR_InputOutputSlot2Type_1
25
TRDHBTR1_HBTR_InputOutputSlot2Data1Value_1
26
TRDHBTR1_HBTR_InputOutputSlot2Data1Result_1
27
TRDHBTR1_HBTR_ExternVerificationFlags_1
28
TRDHBTR1_HBTR_VerificationDateTime_2
29
TRDHBTR1_HBTR_VerificationCounter_2
30
TRDHBTR1_HBTR_OperationHours_2
31
TRDHBTR1_HBTR_VerificationOverallResult_2
32
TRDHBTR1_HBTR_VerificationSensorResult_2
33
TRDHBTR1_HBTR_VerificationSensElectronicResult_2
34
TRDHBTR1_HBTR_VerificationInputOutputResult_2
35
TRDHBTR1_HBTR_VerificationSupplyVoltageResult_2
200
Name
17.1.8
Transducer Block Heartbeat Results 1
Name
Proline Prowirl R 200 FOUNDATION Fieldbus
Label
Data type
Static Revision
UINT16
Strategy
UINT16
Alert Key
UINT8
Transducer Type
ENUM16
External device
STRING
information
Plant operator
STRING
Location
STRING
Label
Data type
UINT16
Transducer Error
ENUM8
Collection Directory
UINT32
Block error
BIT_ENUM32
description
Date/time
STRING
Verification ID
UINT16
Operating time
STRING
Overall result
ENUM16
Sensor
ENUM16
Pre-amplifier
ENUM16
module
I/O module
ENUM16
Supply voltage
ENUM16
External device
STRING
information
Slot 2 Modul Type
ENUM16
Output 2 actual
FLOAT
value 1
Output 2
ENUM16
External verification
BIT_ENUM32
flags
Date/time
STRING
Verification ID
UINT16
Operating time
STRING
Overall result
ENUM16
Sensor
ENUM16
Pre-amplifier
ENUM16
module
I/O module
ENUM16
Supply voltage
ENUM16
Storage
Size
MODE_BLK
Class
(Bytes)
Static
2
Static
2
AUTO
Static
1
AUTO
Static
2
Static
32
AUTO
Static
32
AUTO
Static
32
AUTO
Storage
Size
MODE_BLK Wri-
Class
(Bytes)
Static
2
Dynamic
1
Static
4
Dynamic
4
Static
20
Static
2
Static
14
Static
2
Static
2
Static
2
Static
2
Static
2
Static
32
Static
2
Static
4
Static
2
Static
4
Static
20
Static
2
Static
14
Static
2
Static
2
Static
2
Static
2
Static
2
Endress+Hauser
Wri-
tabi-
lity
X
X
X
X
X
tabi-
lity

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis