Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 215

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Prowirl R 200 FOUNDATION Fieldbus
Rela-
tive
Index
14
TRDHBTR4_BlockErrDesc_1
15
TRDHBTR4_HBTR_VerificationDateTime_7
16
TRDHBTR4_HBTR_VerificationCounter_7
17
TRDHBTR4_HBTR_OperationHours_7
18
TRDHBTR4_HBTR_VerificationOverallResult_7
19
TRDHBTR4_HBTR_VerificationSensorResult_7
20
TRDHBTR4_HBTR_VerificationSensElectronicResult_7
21
TRDHBTR4_HBTR_VerificationInputOutputResult_7
22
TRDHBTR4_HBTR_VerificationSupplyVoltageResult_7
23
TRDHBTR4_HBTR_ExternalDeviceInfo_7
24
TRDHBTR4_HBTR_InputOutputSlot2Type_7
25
TRDHBTR4_HBTR_InputOutputSlot2Data1Value_7
26
TRDHBTR4_HBTR_InputOutputSlot2Data1Result_7
27
TRDHBTR4_HBTR_ExternVerificationFlags_7
28
TRDHBTR4_HBTR_VerificationDateTime_8
29
TRDHBTR4_HBTR_VerificationCounter_8
30
TRDHBTR4_HBTR_OperationHours_8
31
TRDHBTR4_HBTR_VerificationOverallResult_8
32
TRDHBTR4_HBTR_VerificationSensorResult_8
33
TRDHBTR4_HBTR_VerificationSensElectronicResult_8
34
TRDHBTR4_HBTR_VerificationInputOutputResult_8
35
TRDHBTR4_HBTR_VerificationSupplyVoltageResult_8
36
TRDHBTR4_HBTR_ExternalDeviceInfo_8
37
TRDHBTR4_HBTR_InputOutputSlot2Type_8
38
TRDHBTR4_HBTR_InputOutputSlot2Data1Value_8
39
TRDHBTR4_HBTR_InputOutputSlot2Data1Result_8
40
TRDHBTR4_HBTR_ExternVerificationFlags_8
41
TRDHBTR4_STD_LockingState_1
42
TRDHBTR4_STD_UserLevel_1
43
TRDHBTR4_SU_VolumeFlow_1
44
TRDHBTR4_SU_MassFlow_1
45
TRDHBTR4_SU_Density_1
46
TRDHBTR4_SU_Temperature_1
47
TRDHBTR4_STD_SWOptionActiveOverview_1
Endress+Hauser
Name
Label
Data type
Block error
BIT_ENUM32
description
Date/time
STRING
Verification ID
UINT16
Operating time
STRING
Overall result
ENUM16
Sensor
ENUM16
Pre-amplifier
ENUM16
module
I/O module
ENUM16
Supply voltage
ENUM16
External device
STRING
information
Slot 2 Modul Type
ENUM16
Output 2 actual
FLOAT
value 1
Output 2
ENUM16
External verification
BIT_ENUM32
flags
Date/time
STRING
Verification ID
UINT16
Operating time
STRING
Overall result
ENUM16
Sensor
ENUM16
Pre-amplifier
ENUM16
module
I/O module
ENUM16
Supply voltage
ENUM16
External device
STRING
information
Slot 2 Modul Type
ENUM16
Output 2 actual
FLOAT
value 1
Output 2
ENUM16
External verification
BIT_ENUM32
flags
Locking status
BIT_ENUM16
Access status
ENUM16
tooling
Volume flow unit
ENUM16
Mass flow unit
ENUM16
Density unit
ENUM16
Temperature unit
ENUM16
Software option
BIT_ENUM32
overview
Storage
Size
MODE_BLK Wri-
Class
(Bytes)
Dynamic
4
Static
20
Static
2
Static
14
Static
2
Static
2
Static
2
Static
2
Static
2
Static
32
Static
2
Static
4
Static
2
Static
4
Static
20
Static
2
Static
14
Static
2
Static
2
Static
2
Static
2
Static
2
Static
32
Static
2
Static
4
Static
2
Static
4
Dynamic
2
Static
2
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
Anhang
tabi-
lity
X
X
X
X
215