Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Prowirl R 200 FOUNDATION Fieldbus Betriebsanleitung Seite 193

Wirbeldurchfluss-messgerät
Vorschau ausblenden Andere Handbücher für Proline Prowirl R 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Prowirl R 200 FOUNDATION Fieldbus
Rela-
tive
Index
DISP_BackupAction
DISP_StateOfCompDisplayAndDevice
DISP_IsBacklightAvailable
DISP_IsCloneAvailable
DISP_IsRestoreAvailable
DISP_FixDisplayedInput
STD_LanguagesSupported
MDI_ModuleID
TRDDISP_View3
TRDDISP_StRev
TRDDISP_BlockErr
TRDDISP_TransducerType
TRDDISP_XdError
TRDDISP_BlockErrDesc_1
STD_LockingState
SPV_OperationHours
TRDDISP_View4
TRDDISP_StRev
TRDDISP_Strategy
TRDDISP_AlertKey
TRDDISP_TransducerType
STD_UserLevel
DISP_LockingState
DISP_InputSelector01
DISP_DecimalPlaces01
DISP_InputSelector02
DISP_DecimalPlaces02
DISP_InputSelector03
DISP_DecimalPlaces03
DISP_InputSelector04
DISP_DecimalPlaces04
DISP_DeviceDateTimestamp
STD_SWOptionActiveOverview
MDI_ModuleAvailable
MDI_ModuleFirmwareRevision
DISP_Value01_0Percent
DISP_Value01_100Percent
DISP_Value03_0Percent
Endress+Hauser
Name
Languages supported BIT_ENUM32
Access status tooling
0% bargraph value 1
100% bargraph value
0% bargraph value 3
Label
Data type
Configuration
ENUM16
management
Comparison result
ENUM16
Backlight
ENUM16
Is clone available
UINT8
Is restore available
UINT8
ENUM16
Module ID
UINT16
View -3-
VIEW3
Static Revision
UINT16
Block Error
BIT_ENUM16
Transducer Type
ENUM16
Transducer Error
ENUM8
Block error
BIT_ENUM32
description
Locking status
BIT_ENUM16
Operating time
STRING
View -4-
VIEW4
Static Revision
UINT16
Strategy
UINT16
Alert Key
UINT8
Transducer Type
ENUM16
ENUM16
Locking status
ENUM16
Value 1 display
ENUM16
Decimal places 1
ENUM16
Value 2 display
ENUM16
Decimal places 2
ENUM16
Value 3 display
ENUM16
Decimal places 3
ENUM16
Value 4 display
ENUM16
Decimal places 4
ENUM16
Last backup
STRING
Software option
BIT_ENUM32
overview
Resource available
UINT8
Software revision
UINT32
FLOAT
FLOAT
1
FLOAT
Storage
Size
MODE_BLK Writa-
Class
(Bytes)
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
1
AUTO
Static
1
AUTO
Static
2
AUTO
Static
4
Static
2
AUTO
Dynamic
31
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Dynamic
14
Static
90
Static
2
Static
2
AUTO
Static
1
AUTO
Static
2
Static
2
Static
2
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
14
AUTO
Static
4
Static
1
Static
4
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Anhang
bility
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
193

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis