Error Codes:
EH60 - Room temperature sensor error - Unplug the unit and plug it back in. If error
EH61 - Tube Temperature sensor of the evaporator error - Unplug the unit and plug it
EH0b - Display board and master control board communication error.Unplug the unit
Protection Code:
P2 -
Eb -
G
NOTE
When one of the above malfunctions occurs, turn off the unit, and check for
any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer or its service
agents or a similar qualified person for service.

CONTROL PANEL FEATURES

Auto Defrost
When forst builds up on the evaporator coils, the compressor will cycle off and the fan will
continue to run until the frost disappears.
Note: When Auto defrosting operation, the unit may make a voice of refrigerant flowing,
it is normal.
Auto Shut Off
The dehumidifier shuts off when the bucket is full. For some models, the fan motor will
continue to run for 30 seconds.
Wait 3 minutes before resuming operation After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the unit. Operation will automatically
start after 3 minutes.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous
function setting automatically when the power resumes.
Continuous dehumidifying mode
At continuous dehumidifying mode, the unit dehumidify continuously and cannot select
humidity. Press mode button to exit continuous dehumidifying mode.
Smart dehumidifying mode(On some models)
At smart dehumidifying mode, the unit will automatically control room humidity in a
comfortable range 45%~55% according to the room temperature. The humidity setting
function will be invalid.
Setting dehumidifying mode
At setting dehumidifying mode, the unit can be adjusted in a range 35%~85%, and the
humidity setting can be adjusted (increase/decreasing) in 5%. Press MODE button to exit
4
setting dehumidifying mode.
80
repeats, call for service;
back in. If error repeats, call for service;
and plug it back in. If error repeats, call for service;
Bucket is full - Empty the bucket and replace it in the right position.
Bucket malfunction--Replace the bucket in the right position, the malfunction
clear.