Oil Heater
K 160 eco-e

Manual operation

If heating operation is selected, the unit operates in the first heating stage. After 30 seconds, the
nd
2
heating stage is activated. At a temperature above 70 °C at the heat exchanger, the 2
heating stage is deactivated again. At a temperature above 85 ° C, the burner is completely
switched off. As soon as the specified temperatures are undercut again, the respective stages
are activated again.
The monitoring window can be changed using keys 3 + 4 in the main menu. The unit status is
not changed.
Manual operation can be exclusively operated without room thermostat.

Automatic operation

All manuals and user guides at all-guides.com
Here, the K 160 eco-e can be switched into heating
operation. The unit can also be vented in three stages.
Using the arrow keys and the OK key, it is possible to scroll through
the menu. The automatic mode is switched on/off using the
Start/Stop button. During operation, the button is shown in green.
Otherwise, in red.
Using the Target Temperature button, the desired room temperature
can be set.
The Actual Temperature button indicates the current room
temperature.
On pressing the OK key, the Heating Status sub-menu is entered.
The current burner stage, current fan stage, and the target/actual
temperatures are displayed. On actuating the OK key, the menu is
exited again.
Using the Night-time Reduction button, the Night-time Reduction
menu is entered. The following parameters can be adjusted in the
menu:
Night-time reduction: The target value is changed to the
adjusted temperature at night between the adjusted start and stop
time. Night deactivation: The burner switches off between the
adjusted start and stop time.