Troubleshooting table

Malfunctions can occur in all electrical appliances. This does not necessarily mean there is a
defect in the appliance. For this reason, please check the tables to see if you can correct the
malfunction.
WARNING
Risk of electric shock in case of improper repair!
Never try to repair a defective or suspected defective appliance yourself. You can put
your own and future users' lives in danger. Only authorised specialists are allowed to
carry out this repair work.
Problem
Fans and lighting not
working.
Lighting not working.
Grease is dripping off
the appliance
Circulation air opera-
tion:
Odours are not ad-
equately removed;
weak airflow.
Exhaust air operation:
Poor performance.
Possible causes
The appliance is dis-
connected from the
mains.
LED bulb is defective. Contact an electrician.
Grease filter is
clogged.
Grease filter is
clogged.
The exhaust hood
does not have a suffi-
cient air supply.
The exhaust air hose
is bent or too long.
Troubleshooting table
Solutions, tips
Check to ensure that the mains plug is posi-
tioned correctly. Check the socket by connect-
ing another electric device. Check the fuse.
Clean the grease filter (see page EN-20).
Clean the grease filters and/or renew the acti-
vated charcoal filters (starting at page EN-20).
The exhaust hood expels a large amount
of exhaust air. This is why you need to pro-
vide a sufficient air supply, e.g. by providing
non-sealable openings in doors, windows and
ventilation conduits.
Note the safety notices starting on page
EN-4.
Check whether the exhaust air hose is bent or
too long.
Page EN-23