All manuals and user guides at all-guides.com
15. WARNING AND ERROR MESSAGE
It incorporates a variety of functions for the systems to verify processes and the
state of the electronics. In case of an error the screen will display the cause of error
and emit an audible sound.
CONNECT ERROR
CHECK
MAIN
PORT
BALANCE CONNECT
ERROR
DC IN TOO LOW
DC IN TOO HIGH
CELL ERROR
LOW VOLTAGE
CELL ERROR
HIGH VOLTAGE
CELL ERROR
VOLTAGE-INVALID
CELL NUMBER
INCORRECT
INT.TEMP.TOO HI
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
OVER TIME LIMIT
BATTERY WAS FULL
Incorrect polarity connected.
The battery is interrupted.
The Battery connection is wrong.
The balance connect is wrong.
Input voltage less than 11V.
Input voltage higher than 18V.
Voltage of one cell in the battery pack is too low.
Voltage of one cell in the battery pack is too high.
Voltage of one cell in the battery pack is invalid.
The cell number is wrong.
The internal temperature of the unit goes too high.
The external temperature of the unit goes too high.
The battery capacity is more than the maximum capacity
which the user sets.
The charging time is longer than the maximum charging
time which the user sets.
The battery voltage is higher than the maximum voltage
which the user sets when charging in balance mode.
25