2. Handling
2
2.1 Reception check
2.2 Transportation and storage
2.
HANDLING
Immediately upon receipt, check the motor
for external damage (e.g., shaft ends, flanges
and painted surfaces) and if found, inform the
forwarding agent without delay.
The motor should always be stored indoors
at an ambient temperature between 0 °C
and 40 °C, in dry, vibration- and dust-free
conditions.
During transportation, shocks, falls and
humidity should be avoided. Under other
conditions, please contact ABB.
Unprotected machined surfaces (shaft ends and
flanges) should be treated against corrosion.
It is recommended that the shafts are rotated
periodically by hand to prevent grease migration.
Check:
• Motor "Type" code
• Rated voltage "Vn"
• Rated power "Pn"
• Rated speed "wn"
• Maximum speed "wm"
• Manufacturing details "IP.."
• Transducer type "Feedback"
• Data of the parking "brake" if present
• "Fan" ratings.
It is recommended to use anti-condensation
heaters, if fitted, to prevent water from
condensing in the motor.
The motor must not be subject to any external
vibrations at a standstill so as to avoid causing
damage to the bearings.
When starting the motor for the first time,
run the motor slowly for a brief run-in time.
7
EN