LIST OF POSSIBLE PROBLEMS
PROBLEM
The cleaner is slow or doesn't move.
The cleaner stops at walls, steps, the lad-
der, etc.
The cleaner tails to climb the vertical walls of
a cement or gunite pool.
The cleaner reaches the surface and takes
in air

WARRANTY CONDITIONS

The NAVIGATOR is warranted to be free from detects in material and workmanship for (2) two years from
the date of purchase. All warranty claims would be including the proof of purchase indicating the date.
We invite you to keep your receipt.
Hayward warranty is limited to the replacement or repair, at our option, of defective products that have
been used in normal conditions and accordingly to the instruction leaflet, with no change in the product
and that have been working only with genuine Hayward parts. Frost and chemical reaction damages are
excluded of the warranty.
Hayward will not be responsible for all other costs (removal, labour reinstallation...), neither direct nor indi-
rect damages caused by malfunction of the defective product.
The limited warranty excludes the following motion devices: hoses, shoes, wings, flaps, A. frame and
pads.
To initiate a warranty claim and ask for repair or replacement of a product, please contact your dealer. No
shipment to our factory will be accepted without our preliminary written acceptance.
All manuals and user guides at all-guides.com
6
CAUSE
Not enough flow through the cleaner.
Partial blockage of the suction opening of
the Navigator.
Pads worm.
Wings worn
Suction too weak.
Pads or wings worn.
Hose too short.
Failure of steering system.
Not enough flow through the cleaner.
Partial blockage of the suction opening of
the Navigator
Pads worn.
Wings worn.
Hose too short.
Wrong rear flap tension.
Too much flow through the cleaner.
Wrong rear flap tension.
Failure of steering system.
SOLUTION
Clean the prefilter and the filtration system.
Check the vacuum with the vacuum gauge.
Clear the blocked opening.
Replace the pads (figure 8).
Replace the wings (figures 9 and 10).
Check the vacuum with the vacuum gauge.
Replace the pads (figure 8) or wings (fig 9. 10).
Add lengths as explained In the directions for use.
Check and clean the back grate. Check that
the cone transmission mechanism turns
freely in both directions. Check and neces-
sary replace the guidance system.
Clean the prefilter, and the filtration system.
Check the vacuum with the vacuum gauge.
Clear the blocked opening.
Replace the pads (figure 8).
Replace the wings (figures 9 and 10).
Add lengths as explained In the directions for use.
Set the rear flap adjustment knob to III (figure 3).
Clean the prefilter, and the filtration system.
Check the vacuum with the vacuum gauge.
Set the rear flap adjustment knob to I (figure 3).
Check and clean the back grate. Check that
the cone transmission mechanism turns free-
ly in both directions. Check and if necessary
replace the guidance system.