5 minutes for your safety
Safety instructions and warnings for the gas pressure springs
The gas pressure spring is pressurised and must not be opened!
installed in the extractor hood
The piston rod must not be deformed or damaged or come into
contact with paint, dirt, acids, adhesive or aggressive agents.
Never try to exchange or repair defective or supposed defective gas
pressure springs. There is a risk to yourself and other users. The
gas pressure springs may only be replaced by authorised specialists.
Please dispose of the gas pressure springs properly and in an
environmentally friendly manner.
Inform people who are not aware of the instructions or do not
understand them about the safety instructions and warnings
above!
Special safety information for extraction mode
The fan extracts air from the room in which the extraction hood
Risk of toxication/fire!
is operated and transports it outside. If fireplaces depending on
the room air are simultaneously in use in this room (e.g. gas or
other fuel-powered heating systems), these can be withdrawn the
combustion of the necessary oxygen. This can result in the flame
going out and gas escaping or the exhaust gas being sucked into the
room.
Operation without risk is possible when, e.g. the air for combustion
can flow through non-closing apertures in doors, windows or
wallboxes and when a maximum vacuum of 0.04 bar can be attained
in the room where installed. Thereby, back suction of the exhaust
gases is prevented.
To evaluate the required actions, always observe overall associated
ventilation of the living quarters. Consult the competent official
heating inspector.
Never connect the extraction hood to a ventilation duct or room or
flue!The extracted air must not be routed into a channel in which
warm air circulates. The extracted air must only be routed to the
outside in a separate air channel only provided for the extraction

hood.

For operation in extraction mode, a wall breakthrough is required.
Important!
We recommend that you commission a specialist firm (electrical
installation) to make this opening (core drilling).
Consider: The shorter the extraction pipe is and the fewer bends it
has, the greater the effect of the extraction hood.
There are different authority regulations in the different federal
states with regard to dealing with discharge of the exhaust air. Ask
your local official heating inspector for advice.