Micropulse Transducer - Rod Style
9
Calibration using online setting
NOTICE!
Interference in function
Changing the transducer output signal may result in
personal injury and equipment damage if the system is
ready for operation.
Persons must keep away from the system's
hazardous zones.
1. Set start value online:
Move the system so that the magnet is in the start
position.
Hold down
for at least 3 s.
Hold down
and additionally press
for at least 3 s.
Buttons are activated.
Set start value.
Using
and
, you can change the start value
within the permissible setting range
of the output remains constant (see page 16).
Exit setting (do not press a button for at least 15 s).
The start value is saved, the buttons are
deactivated.
After each calibration procedure you must wait for the
lockout time of 15 s. This also applies to switching
between the start value and end value setting.
2. Set end value online:
Move the system so that the magnet is in the end
position.
Hold down
for at least 3 s.
Hold down
and additionally press
for at least 3 s.
Buttons are activated.
Set end value.
Using
and
, you can change the end value
within the permissible setting range
of the output is changed, but the zero value
remains unchanged (see page 16).
Exit setting (do not press a button for at least 15 s).
The end value is saved, the buttons are
deactivated.
1) Briefly press button: Current value is increased or
decreased by approx. 1 mV or 1  A.
If a button is held down longer than 1 s, the step
interval is increased.
www.balluff.com
All manuals and user guides at all-guides.com
In online setting the system is not shut down. The start and
end values are set online.
Maximum setting range for each calibration
procedure:
Start value:
End value:
If the desired value cannot be attained in the first
calibration procedure (max. setting range exceeded), the
calibration procedure must be started again.
> 3 s
+
> 3 s
1
1
1)
. The gradient
2
2
> 3 s
+
> 3 s
1
1
1)
. The gradient
2
2
LED legend:
LED not on
LED green
±25% of present stroke
±25% of present output value
LED display
Displayed values (example)
LED1 LED2 At 0 to 10 V
1
1
2
LED display
Displayed values (example)
LED1 LED2 At 0 to 10 V
2
2
1
LED 1 and LED 2 flashing green-red in alternation
LED 1 and LED 2 flashing red-green in alternation
At 4 to 20 mA
5.39 V
12.62 mA
5.39 V
12.62 mA
5.39 V
12.62 mA
4.84 V
11.74 mA
4.84 V
11.74 mA
At 4 to 20 mA
8.72 V
17.95 mA
8.72 V
17.95 mA
8.72 V
17.95 mA
9.49 V
19.18 mA
9.49 V
19.18 mA
21
english

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis