3.4.3.6
Menu "Communication"
Here settings for the Ethernet port (on rear side of device) are made. The USB port there doesn't require any settings.
When delivered or after a complete reset, the Ethernet port has following default settings assigned:
• DHCP: off
• IP: 192.168.0.2
• Subnet mask: 255.255.255.0
• Gateway: 192.168.0.1
• Port: 5025
• DNS: 0.0.0.0
• Host name: Client
• Domain: Workgroup
Those settings can be changed anytime at will, in the setup menu or via the device website, which you can open
from the current IP or host name (also see 2.3.12).
Submenu "IP Settings 1"
Element
Description
Get IP address Manual (default): uses the default (after delivery or reset) or the last set network parameters.
Those parameters are not overwritten by selection "DHCP" and remain when switching back
from "DHCP" to "Manual"
DHCP: after switching to DHCP and submitting the change with button
instantly try to get network parameters (IP, subnet mask, gateway, DNS) assigned from a DHCP
server. If the attempt fails, the device will use the settings from "Manual" again. In this case, the
overview in screen "View settings" will indicate the DCHP status as "DHCP (failed)", otherwise
as "DHCP(active)"
IP address
Only available with setting "Get IP address = Manual". Default value: 192.168.0.2
Permanent manual setting of the device's IP address in standard IP format
Subnet mask
Only available with setting "Get IP address = Manual". Default value: 255.255.255.0
Permanent manual setting of the subnet mask in standard IP format
Gateway
Only available with setting "Get IP address = Manual". Default value: 192.168.0.1
Permanent manual setting of the gateway address in standard IP format
Submenu "IP Settings 2"
Element
Description
Port
Default value: 5025
Adjust the socket port here, which belongs to the IP address and serves for TCP/P access when
controlling the device remotely via Ethernet
DNS address
Default value: 0.0.0.0
Permanent manual setting of the network address of a domain name server (short: DNS) which
has to be present in order to translate the host name to the device's IP, so the device could
alternatively access by the host name
Submenu "Com Proto." (communication protocols)
Element
Description
Enabled
Default value: SCPI&ModBus
Enables or disables SCPI or ModBus communication protocols for the device. The change is
immediately effective after submitting it with ENTER button. Only one of both can be disabled.
Submenu "Com Timeout" (communication timeout)
Element
Description
Timeout USB (ms) Default value: 5
Communication timeout in milliseconds. Defines the max. time between two subsequent
bytes or blocks of a transferred message. For more information about the timeout refer to
the external programming documentation "Programming ModBus & SCPI".
Timeout ETH (s)
Default value: 5
Adjustable time, after which the device will automatically disconnect the socket connection,
if there was no communication during that period
EA Elektro-Automatik GmbH
Page 34
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
, the device will
www.elektroautomatik.de
ea1974@elektroautomatik.de

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis