PS 9000 1U Series
This area furthermore displays various status texts:
Display
Description
Locked
The HMI is locked
Remote
The device is under remote control from...
Analog
...the built-in analog interface
USB
...the built-in USB port or a plug in interface module
Ethernet
...the built-in Ethernet/LAN port
Local
The device has been locked by the user explicitly against remote control
1.9.4.2

Rotary knobs

As long as the device is in manual operation, the two rotary knobs are used to adjust set values, as well
as setting the parameters in the settings menu. For a detailed description of the individual functions see
section „3.4 Manual operation" on page 31.
1.9.4.3
Pushbutton function of the rotary knobs
The rotary knobs also have a pushbutton function which is used in all menu options for value adjustment to move
the cursor by rotation as shown:
1.9.4.4
Resolution of the displayed values
In the display, set values can be adjusted in fixed increments. The number of decimal places depends on the
device model. The values have 4 or 5 digits, while actual and set values related to the same physical unit always
have the same number of digits.
Adjustment resolution and number of digits of set values in the display:
Voltage,
OVP, U-min, U-max
Nominal
Min. increment
80 V
4 0.01 V
200 V
5 0.01 V
360 V / 500 V 4 0.1 V
750 V
4 0.1 V
In manual operation every set value can be set in the increments given above. In this case
the actual output values set by the device will lie within percentage tolerances as shown in the
technical data sheets. These will influence the actual values.
1.9.5

Share Bus-Connection

The 2 pole WAGO socket ("Share") on the back side of the device is provided for
connection to equally named sockets on compatible power supplies series to achieve
a balanced load current distribution during parallel connection of up to 10 units. It is
furthermore use Following power supply series are compatible:
• PSI 9000 2U
• PSI 9000 3U
• ELR 9000
• EL 9000 B
* From hardware revision 2, see type label (in case it does not show "Revision" on type label, it is revision 1)
EA Elektro-Automatik GmbH
Page 20
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Current,
OCP, I-min, I-max
Nominal
Min. increment
6 A
4
0.001 A
10 A / 12 A
5
0.001 A
15 A / 20 A
5
0.001 A
25 A
5
0.001 A
30 A / 50 A
4
0.01 A
100 A
5
0.01 A
• PSE 9000
• PS 9000 2U *
• PS 9000 3U *
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
Power,
OPP, P-max
Nominal
Min. increment
1500 W
4 1 W
3000 W
4 1 W
www.elektroautomatik.de