Tab. 58:
Byte Content
14
ACA removed
15
Not used
16
Not used
17
Connection
Tab. 59:
Byte Content
0
Report port error
1
Report connection error
2
Transmission rate too high
3
Port on
4
Link status
5
Bit rate
6
Duplex
7
Autonegotiation
UM Config RSPE
Release 9.0 12/2021
Gerätestatus
Access
ro
ro
Port-Status/Port-Parameter
Value
Meaning
0
Unavailable
1
OK
2
The ACA has been removed.
0
1
2
0
1
2
0
Unavailable
1
OK
2
Connection failure
Access
Value
Meaning
rw
0
Do not send an alarm.
1
When one of the port alarm reasons
represented by bytes 4 .. 10 occurs,
send an alarm.
rw
0
Do not send an alarm.
1
Send alarm if the connection has failed.
rw
0
Do not send an alarm.
1
When the threshold values for the
transmission rate are exceed, send an
alarm.
rw
0
Unavailable
1
Port enabled
2
Port disabled
ro
0
Unavailable
1
Connection exists
2
Connection interrupted
ro
0
Unavailable
1
Unknown
2
10 MBit/s
2
100 MBit/s
2
1000 MBit/s
ro
0
Unavailable
1
Half duplex
2
Full duplex
ro
0
Unavailable
1
Disabled
2
Enabled