Herunterladen Diese Seite drucken

Belden HIRSCHMANN RSPE Referenzhandbuch Seite 733

Grafische benutzeroberfläche
Vorschau ausblenden Andere Handbücher für HIRSCHMANN RSPE:

Werbung

Industrieprotokolle
16.3 EtherNet/IP
Tab. 48:
Id
Attribute
0x69 Broadcast limit
0x6A Ethernet Interface
Description
0x6B Port Monitor
0x6C Quick Connect
308
Hirschmann-Erweiterungen des Ethernet-Link-Objekts (Forts.)
Access
Rule
Get/Set USINT
Get/Set STRING
Get/Set DWORD
Get/Set USINT
Data type
Description
Broadcast limiter Service
(Egress BC-Frames limitation, 0=disa-
bled), Frames/second
Interface/Port Description
(from MIB II ifDescr), for example
"Unit: 1 Slot: 2 Port: 1 - 10/100 Mbit TX"
or
"unavailable", max. 64 Bytes.
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12: Reserved (always 0)
13: Reserved (always 0)
14: Reserved (always 0)
15: Reserved (always 0)
Quick Connect on the interface
(0=Off, 1=On)
If you enable Quick Connect, then the
device sets the port speed to 100FD,
disables Auto-Negotiation, and Span-
ning Tree on the interface.
Link Flap (0=Off, 1=On)
CRC/Fragment (0=Off, 1=On)
Duplex Mismatch (0=Off, 1=On)
Overload-Detection (0=Off, 1=On)
Link-Speed/ Duplex Mode
(0=Off, 1=On)
Deactivate port action (0=Off,
1=On)
Send trap action (0=Off, 1=On)
Active Condition (displays which
condition caused an action to
occur)
00001
: Link Flap
B
00010
: CRC/Fragments
B
00100
: Duplex Mismatch
B
01000
: Overload-Detection
B
10000
: Link-Speed/ Duplex
B
mode
UM Config RSPE
Release 9.0 12/2021

Werbung

loading