Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions; Technical Specifications "Overview; Electrical Data - ECOLAB Elados EMP IV E00 Betriebsanleitung

Membrandosierpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11.2

Dimensions

Fig. 11.1
capacity
type
00140
00210
00450
00630
00750
11.3

Technical specifications "Overview"

11.3.1

Electrical Data

Description
Supply voltage
max. power consumption I
max. starting current I
Motor Power
Fuse rating
Type of protection
Breaking capacity at circuit with 24 V
Breaking capacity at circuit with 230 V
417101090_EMP_IV_E00_E10
All manuals and user guides at all-guides.com
A
C
133,5
170
133,5
170
142,5
190
142,5
220
142,5
220
115V 50/60 Hz
N
230V 50/60 Hz
3PE 400V 50 / 60 Hz
(≈ I
∗ 3,3)
A
N
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
115 V
230 V
Empty report output
stroke signal output
Empty report output
stroke signal output
measurement [mm]
C1
L
H1
174
392
280
174
392
280
194
412
303,5
225
412
318,5
225
412
318,5
01400
02100
230 V / 50/60 Hz ± 10 %
(special voltages on request)
24 V 3 A AC/DC
230 V / 3 A AC/DC
connection according to VDE is not permitted
- 54 -
H2
D
216
1¼"
216
1¼"
263
2"
293
2"
293
2"
Pump type
04500
06300
07500
5.1 / 7.6 A
2.5 / 3.8 A
1.2 / 1.05 A
16.8 / 25.1 A
8.25 / 12.5 A
4.0 / 3.5 A
0.3 kW
0.3 kW
0.37 kW
12.5 A
6.3 A
IP 55
24 V 0.3 A DC
Rev. 8-06.13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Elados emp iv e10

Inhaltsverzeichnis