Heizkörperthermostat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6x long red
flashing
Short orange
lighting (after
green or red
confirmation)
MANU
Battery
BOOST
information (
MANU
Battery
BOOST
information (
and ---
*If empty batteries are not replaced, the radiator thermostat
moves to a "valve error position". This avoids, that the set
temperature in the room cannot be reached any more due to
a low battery. A valve error position of 15 % is set in the factory
settings.
1x orange and 1
x green lighting
(after inserting
batteries)
Long and short
orange flashing
(alternating)
Device
defective
Batteries
empty
Battery volt-
)
age low
C
Valve moved
)
to error
C
position*
Test display
Device soft-
ware update
(OTAU)
Troubleshooting
Have a look at your
app for error mes-
sage or contact your
retailer.
Replace the batteries
(see "7 Replacing
batteries" on page
56).
Replace the batteries
of the device (see "7
Replacing batteries"
on page 56).
Replace the batteries
of the device (see "7
Replacing batteries"
on page 56).
Once the test display
has stopped, you can
continue.
Wait until the update
is completed.