R
»R« magnetic internal gear pumps
7. BEARING
7.1 R pumps internal bushes are either lubricated by
the liquid being pumped or are self-lubricating and
require no maintenance.
7.2 Some bearing housing have grease nipples for
lubrication of the external ball bearings. Grease
the bearings every 500 hours operation or every
two months.
8. STORAGE
8.1 If the pump has to be stored for several weeks,
drain the liquid out of the pump casing and clean.
If necessary, flush the pump with a suitable
solvent. Coat the gears with lubricating or rust
preventing oil, grease the bearings and let the
pump run for a few seconds. If the pump is left out
in the open, close the ports and cover it with a
waterproof canvas.
9. GUARANTEE
9.1 The manufacturer guarantees R pumps, supplied
according to the general sales conditions, against
defects or faulty workmanship for a period of 12
months from the date of delivery.
9.2 Repair of the pump or replacement of parts or of
the pump itself can only be carried out after
careful examination of the pump in our workshop
where the pump should be sent by carriage paid.
Any exceptions must be confirmed in writing.
9.3 This guarantee does not cover parts subject to
deterioration or normal wear, or damaged by
misuse or improper handling of the pump by the
user.
9.4 This guarantee is no longer valid if the pump is
disassembled or modified without the
authorization of the manufacturer.