Operation instructions | MK 8-00 | MK 16-00 | MK 8-06 | MK 16-06
2.2.

Mounting in a 19" rack

Note: For 19-inch rack mounting, there must be at least 5 cm clearance in front of and behind the unit.
è Remove the wall bracket from the housing of the compact headend.
è Mount the front plate MKZ 1-00 onto the MK 8 / 16-00 (1).
è Slide the compact headend into the 19 "rack.
è Screw the compact headend with four screws (2).
è Install the device in compliance with the safety regulations defined by the EN 60728-11 standard.
2.3.

Equipotential bonding

è The device must be connected to the equipotential bonding according to EN 60728-11. Use the
equipotential bonding connection at the device (see 3 at page 9).
è To connect the outer conductor of the coaxial cable to the equipotential bonding, use e.g. QEW earthing
angles or CFA earth connection blocks at the inputs and output.
2.4.

Power supply

The headend has a built-in power supply unit. Connect the headend to a mains socket using the enclosed
mains cable. (see 1 at page 9).