User manual / Bedienungsanleitung
While the tonearm is in this position you can hand-tight the clamping ring.
After fixing, you can re-check the setting using the Mini Level Gauge and correct if necessary.
If the position is still correct, you can put the tonearm back in the rest position holder and put the
stylus protector back on.
5.2 Alignment of the tonearm
For the correct alignment of the
alignment gauge (Art. No. AC005/IEC).
Open the clamping ring again, being careful as the height of the tonearm is already adjusted.
Set the distance as following (Pic. 12):
Universal
-
9 inch
Distance from platter to rest position holder
Distance from platter to headshell center
Universal
-
12 inch
Distance from platter to rest position holder
Distance from platter to headshell center
195mm
217mm
Pic. 12: Alignment of the tonearm
Fix the tonearm in the clamping ring and re-check the previous settings again as described and
correct them if necessary.
Page / Seite 12
Universal
tonearm, we recommend to use a ruler or the Clearaudio
Universal
9 inch
= 195mm (± 3mm)
= 217mm (± 3mm)
= 251mm (± 3mm)
= 248mm (± 3mm)
Universal
251mm
248mm
© clearaudio electronic GmbH, 2021-09
12 inch