VDC-295AIOD / VDC-535AIOD
2.6 Setting the dome camera protocol
If a dome camera is to be installed with a SANTEC keyboard, select the Pelco protocol.
Please consult the service personnel if a dome camera is installed with a device other than a
keyboard.
S4
D1
D2
D3
OFF OFF OFF
OFF
ON
OFF
OFF OFF
ON
OFF
ON
ON
OFF OFF OFF
ON
ON
ON
Note:
If you set DIP switch S4 to default factory settings and then connect the camera to power, all
programmed data will be erased. To avoid this, you have to power the camera first and then
set DIP switch S4 to factory settings.
The dome camera can activate external devices such as buzzers or lights. Connect the
device to the NC (NO) (alarm output) and COM (common) connectors.
D1
OFF OFF OFF 2400 Bps
OFF OFF
OFF
OFF
ON
Protocols
D4
OFF
F2, F2E, Pelco D, Pelco P, Ernitec, Philips (default), no parity
OFF
Vicon
OFF
Sensormatic RS-485
OFF
Dynacolor
ON
F2, F2E, Pelco D, Pelco P, Ernitec, Philips, even parity
ON
Default factory settings
S3
Baud Rate
D2
D3
On
4800 Bps
ON
OFF 9600 Bps (default)
ON
ON
19200 Bps
OFF OFF 38400 Bps
7