Installation
WATER CONNECTION (CUBE R)
Drain pipe
A water drain (1) with siphon must be prepared
near the machine.
The drain siphon must be positioned
at least 20 cm below the bearing
plane of the machine.
Connect the drain pipe to the connection of the
drain tray and secure it with the relevant clamp.
Connect the other end of the pipe to the previously
prepared drain pipe.
Intake pipe (CUBE R)
- Connect the supplied water supply pipe by firmly
connecting it to the tap located on the bottom of
the machine.
Connect the intake pipe (2) to a softener (4) with the
impurity filter (3) between them.
- Before the softener (4), install a shuttering tap (5)
to separate the water system from the machine.
1
WARNING: If the line pressure
exceeds 4 bar, install a pressure
reducer. Only supply with cold
water.
For the water mains connection use
hose-sets supplied. When you need
to replace the hose-sets you must
only use a new hose-sets and the
old hose-sets should not be reused.
41
CUBE
2
4
5
3