GREASE M1 SET
4000h
BELT CHANGE SET
4000h
LANGUAGE SELECT
ENGLISH
USER PASSWORD
****
If there is no activity for 60 seconds in the current menu, the control will automatically return to the
main menu.
Factory param
For servicing mode (view with password). Modification only possible by manufacturer.
ADJUST. param
Basic settings and maintenance hour counter (view and change with password).

4.2 Error description

Alarm (warning): The indicator flashes and the machine continues to run.
Error: The indicator is permanently lit, there is an accompanying acoustic signal and the machine
switches off. The error message can be acknowledged after the cause of the error has been resol-
ved. In order to acknowledge the error message, press and hold the 'back to main menu' button.
Alarm (warning, compressor continues to run)
ALARM:
TEMP HIGH 105°C
ALARM: 0110h
OIL FILTER SOON
COMPRAG Screw air compressor A-Series
Lubricate motor bearings. Set maintenance interval
Set value
Change belts. Set change interval
Set value
Language EN/DE
Set value
User password
No access to parameter
Restarting operation without eliminating the cause of the fault
isnot permitted!
Oil/air mixture temperature at the compressor outlet high
Maintenance interval exceeded