LCD Status Display
COMPRAG SCREW
AIR COMPRESSOR
After 5 seconds, the menu will switch main compressor parameters:
TEMP: --°C
SYS STOP C01
Press enter
.
PRES:--.-bar
SYS STOP C01
Select the menu options using the up
RUN PARAMETERS
USAGE PARAM
FACTORY PARAM
ADJUST. PARAM
Run parameters
These parameters apply only to the display of the current settings of the product.
RUN PARAMETERS
MOTOR M1 A-0.0
B-0.0 C-0.0
TOTAL RUN TIME
---h--m
TOTAL LOAD TIME
---h--m
THIS RUN TIME
---h--m
THIS LOAD TIME
---h--m
OIL FILTER TIME
0110h
COMPRAG Screw air compressor A-Series
The display screen will show as below after power on:
Current temperature of the oil-air mixture
Current compressor working status
Current pressure at compressor air outlet
Current compressor working status
and down
Includes current values (available for viewing)
Includes operating settings of the main parameters (available for
viewing, changes password-protected)
For servicing mode (view with password). Modification only possible
by manufacturer
Basic settings and maintenance hour counter (view and change with
password). Modification only possible by distributor's technical staff
Current consumption per phase
Total operating hours (loaded and idle run time)
Current value
Total load hours
Current value
Operating hours since last switched on (loaded and idle run time)
Current value
Load hours since last switched on
Current value
Operating time since last service
Current value
buttons and enter
: