ALARM: 0110h
BELT SERV. SOON
ALARM: 0110h
AIR FILTER SOON
ALARM: 0110h
SEPARATOR SOON
ALARM: 0110h
OIL CHANGE SOON
ALARM: 0110h
GREASE M1 SOON
Alarms for maintenance are triggered at the set time before maintenance. The alarm message is
displayed intermittently and repeatedly in the case of an overrun maintenance interval.
Error messages (compressor stops or does not start)
TEMP: 99°C
EMERG. STOP C01
STOP: PRESSURE
HIGH 10.4bar
STOP:
TEMP HIGH 110°C
TEMP: 0°C
TEMPER LOW C01
STOP: OVERLOAD
M1 CUR. 104.8A
30
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Maintenance interval exceeded
Restarting operation without eliminating the cause of the fault
isnot permitted!
Emergency stop pressed
Max. permissible working pressure of the compressor exceeded
Oil/air mixture temperature at the compressor outlet exceeded
Drop below temperature (oil temperature below 5°C)
Motor M1 permissible current consumption exceeded