Herunterladen Inhalt Inhalt Diese Seite drucken

Dipswitch Setting - Carrier XCT7 Installations- Und Benutzerhandbuch

Kompakte 4-wege-kassette
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 84
Electrical Wiring

Dipswitch setting

Indoor Units PCB
In the following table, 1 represents ON and 0 represents OFF. Definition principles of code switches:
SWO1 is used to set the capabilities of the master and slave indoor units as well as the indoor unit; SW03 is used to set
the address of the indoor unit (combine original communication address and address of centralized controller).
(A) Definition and description of SW01
SW01_1
SW01_2
Address of wire
SW01_3
controlled indoor unit
SW01_4
SW01_5
SW01_6
Capability of indoor
unit
SW01_7
SW01_8
[1]
[2]
[3]
[4]
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
∙∙∙
∙∙∙
∙∙∙
∙∙∙
1
1
1
1
[5]
[6]
[7]
[8]
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
1
0
1
1
0
26
Address of wire controlled indoor unit (group address)
0# (wire-controlled master unit) (default)
1# (wire-controlled slave unit)
2# (wire-controlled slave unit)
3# (wire-controlled slave unit)
4# (wire-controlled slave unit)
5# (wire-controlled slave unit)
∙∙∙
15# (wire-controlled slave unit)
Capability of indoor unit
40VU005C-7S-QEE
40VU007C-7S-QEE
40VU009C-7S-QEE
40VU012C-7S-QEE
40VU016C-7S-QEE
40VU018C-7S-QEE