Installation Procedures
Installing the decorated panel on the body of the indoor unit:
receiving window for the remote the
lamp will not flash when a wired controller is used
• Restrictions for mounting the panel: mount the panel as shown in the figure.
Incorrect direction may cause air leakage
and not allow the swinging and receiving displays to be connected.
• Position it with the screws temporarily to check the placement.
• Screw the two positioning screws and the other 2 screws and fasten them.
• Connect it to the motor line, communication line and power line, and check with the controller if the connections are
correct. Mount the air inlet grid and corner lids after ensuring that the machine can operate normally.
Inappropriate tightening of screws might cause errors as
shown in Fig. 1.
Tighten the screws appropriately.
If there exists distance between the decorated board and the
ceiling after tightening the screws, please readjust the height of
the body of the indoor unit. (Fig. 2)
If the indoor unit horizontal level and the drainpipe aren't influ-
enced, adjust the height of the body of the indoor unit from the
holes on the corners of the decorated board
• Wiring of the decorated board
a. Connect it to the connector of the wind deflector motor lead
on the decorated panel
(Fig. 3);
b. Connect it to the receiving terminal of the remote controller
on the decorated panel.
Attention
air leakage
leakage from
roof
pollution
side of indoor unit
<circuit diagram>
(different from the actu-
al condition)
17
vapour condensate
drops
Fig.1
any distance is not okay
side of the decorated
electrical cabinet
Fig.3