Number / Alarm
Cause
A212
A different axis was programmed in the NC
block following a special function (M7 only).
Special function and
axis combination not
Example:
allowed
N10 G50 X100 F1000
N15 G90 Y200 incorrect
N15 G90 X200 correct
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
A213
The decoded NC block contains several D
numbers.
Multiple D-number not
allowed
Example:
N1 G41 D3 D5.
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
A214
The decoded NC block contains several
mutually exclusive G functions from the
Multiple acceleration
acceleration override group (G30 to G39).
behaviour not allowed
Example:
N1 G34 G35
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
A215
The decoded NC block contains several
mutually exclusive G functions from the
Multiple special
special function group (G87, G88, G89, G50,
functions not allowed
G51).
Example:
N1 G88 G50
The NC program number and NC block
number in which the NC block decoder
detected the error can be read out with the
"output actual values - decoder error location"
task.
Effect:
NC program execution is inhibited or aborted,
the axis is brought to a standstill via the
deceleration ramp.
Siemens AG
6SE7087-6KP50
SIMOVERT MASTERDRIVES
Operating Instructions
Counter-measure
Correct the NC program.The axis used in the
NC block with the special function must also
be programmed in the next NC block.
Correct the NC block.
Correct the NC block.
Correct the NC block.