START SCREEN

Upon ignition, the REC10 might:
- request the setting of the time and date (see paragraph "12.1.1 Time&date" )
- display the firmware version and require a button to be pressed in order to continue.
By pressing the "UP" and "DOWN" keys it is possible to move the selection of the functions
in this order:
- PLANT / STATE / SET / INFO / MENU.
By pressing the "ENTER" key you access the settings of the selected function (except for
). The "BACK" key is inactive (except for
PLANT
FRI
18/05/2013
MENU
INFO
HOT WATER TEMPERATURE
8
PLANT
This item does not represent any specific function.
Instead, it indicates the zone to which the data shown on the start screen refer, and the zone
to which the settings accessible via the other functions refer.
The presence of one or more zones in addition to PLANT depends upon the installa-
tion's configuration. For this reason, one or more of the zones cited below may not be
present in your configuration, or may be identified with a different name.
In order to change zones, highlight PLANT if necessary pressing the "UP" and "DOWN"
keys. Then, pressing the "ENTER" and "BACK" keys, it will be possible to select the other
zones in this sequence:
- PLANT
- MAIN ZONE
- ZONE 1
- ZONE 2.
The TIME&DATE, LANGUAGE and BACKLIGHT settings are independent of the selected
zone. The information contained in the INFO menu is independent of the selected zone.
No domestic hot water parameters can be set if MAIN, ZONE 1 or ZONE 2 is selected.
9
STATE
The
function can be used to set the
STATE
To do this, it is necessary to highlight the desired entry using the "UP" and "DOWN" keys and
then pressing "ENTER" to confirm the selection.
Pressing "BACK" takes you back to the initial screen without making any selection.
28
PLANT
12:17
bar
STATE
1.3
42
°C
INFO
SET
REC10
DOWN key
).
PLANT
PLANT
12:17
bar
STATE
1.3
42
°C
SET
and
operating modes.
BOILER
MAIN ZONE
UP key
9.1
Boiler
This function can be selected in order to set the boiler's status, by choosing one of the
following options:
- OFF - HOT WATER ONLY (SUMMER) - HEATING AND HOT WATER (WINTER).
The highlighted status is that which is currently selected. In order to select a different
status highlight it using the "UP" and "DOWN" keys and then press "ENTER" to confirm
the selection.
Once the selection has been validated, the display returns to the
Press "BACK" to return to the start screen without making any selection.
9.1.1
OFF
If OFF is selected, the system shuts off.
The electrical supply and the fuel supply remain active.
9.1.2
Summer
If HOT WATER ONLY is selected, the system produces domestic hot water.
Heating is not enabled.
9.1.3
Winter
If HEATING AND HOT WATER is selected, the system produces domestic hot water and
activates the heating function.
9.2
Main zone
Selecting this function allows you to set the main zone's status, by choosing one of the
following options:
- if the heating programming timing is not enabled:
- ZONE ON - ZONE OFF
- if the heating programming timing is enabled:
- AUTO - MANUAL - HEAT OFF.
In order to select a different status highlight it using the "UP" and "DOWN" keys and confirm
the selection by pressing "ENTER". Once the selection has been validated, the display
returns to the STATE screen. Press "BACK" to return to the STATE screen without making
any selection.
STATE
BOILER
MAIN ZONE
STATE
BOILER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
MAIN
ZONE ON
ZONE OFF
MAIN
AUTO
MANUAL
HEAT OFF