GB
INSTALLATION INSTRUCTIONS
DECLARATION OF CONFORMITY
The manufacturer declares that all appliances are con-
structed in compliance with EC Directives 90/396, and
stipulates that installation must be carried out in accor-
dance with current standards, with particular attention to
adequate air exchange and combustion gas extraction
system.
N.B. The manufacturer declines all responsibility for all
damage caused directly or indirectly by incorrect instal-
lation, tampering, lack of maintenance, improper use,
and all other cases as indicated in the sales conditions.
- The appliance is designed for catering use and must
be operated exclusively by qualified personnel.
- Read this instruction booklet carefully for indications
regarding installation safety, operation and mainte-
nance.
- The instruction booklet must be kept with the appli-
ance for future reference.
- If the appliance sale is sold or moved to new premises,
always ensure that the booklet is kept with the appli-
ance so that the new owner or installer can refer to
operation instructions and safety warnings.
INSTALLATION STANDARDS AND
SPECIFICATIONS
- Installation, all conversions of the appliance to other
types of gas, appliance start-up, and elimination of
system faults, must be carried out exclusively by
qualified personnel.
- Gas installations and appliance locations must com-
ply with current local regulations; note in particular
that the air required for combustion is 2 m
of installed power. Furthermore, all accident preven-
tion standards must be observed.
fig. 1
FORCED DISCHARGE
HOOD
COWL
N.B. A cowl or wind-proof flue is supplied alternatively according to request.
PRELIMINARY INSTALLATION PROCEDURES
- Remove the appliance from the packaging and
- Remove all plastic adhesive film from parts before
- Protect all wall coverings in the vicinity of the appliance
EXTRACTION SYSTEM
The installation location must be fitted with suitable
extraction systems in compliance with the installation
standards. Our appliances are classified as follows (see
technical specifications table):
- "B11" type gas appliances
- If combustion products are discharged by means of a
- The gas supply to the appliance must be equipped
3
/h per kW
E
1
ensure, by means of a spirit level, that the appliance
is installed on a flat level floor. If necessary, adjust
appliance height by means of the feet or other devices.
using the appliance. Clean parts thoroughly to remove
all adhesive residue. (Do not use abrasive
substances).
against heat by fitting suitable refractory sheets, or
install the appliance at least 100 mm from side or
rear walls.
Designed for connection to natural extraction system,
such as an efficient natural extraction flue, by means
of an extraction system connected directly to the
outside, or connection to a forced extraction system,
such as an extraction hood fitted with a suction fan.
forced extraction system:
with a forced extraction system; and must shut off
when the extraction capacity falls below the specified
values. Gas supply can only be restored manually.
fig. 2
NATURAL DISCHARGE
WINDPROOFING
DEVICE