9.4 IO-Link Port 1..8 – Einstellungen
Konfigurations-
Byte-Offset
Parameter
Konfig.-
Assembly
IOL Failsafe
231, 263, 295, 327,
359, 391, 423, 455
Port Mode
232, 264, 296, 328,
360, 392, 424, 456
Validation and
233, 265, 297, 329,
Backup
361, 393, 425, 457
Vendor ID
234, 266, 298, 330,
362, 394, 426, 458
Device ID
238, 270, 302, 334,
366, 398, 430, 462
64
Datentyp
Gültige Werte
SINT
0: Set Low
1: Set High
2: Hold Last
3: Replacement Value
(transferred via IO-Link
Failsafe Parameter
Object)
4: IO-Link Master
Command
SINT
0: Deactivated
1: Manual (with
validation and backup
config)
2: Autostart (no
validation and backup
config)
SINT
0: No device check
and clear (no data
storage)
1: Type compatible
V1.0 device (no data
storage)
2: Type compatible
V1.1 device (no data
storage)
3: Type compatible
V1.1 device with
Backup + Restore
(download + upload)
4 Type compatible V1.1
device with Restore
(download master to
device)
DINT
0..65535 (0)
0..16777215 (0)
DINT
9 Konfigurations-Parameter
CIP-Objektklasse
0xA3, Instanz
1..8
Attribute 8
Attribute 9
Attribute 10
Attribute 11
Attribute 12
Handbuch EtherNet/IP