14.3 REST API
14.3.2 Struktur
Name
Datentyp
name
string
order-id
string
fw-version
string
hw-version
string
mac
string
bus
number
failsafe
number
ip
string
snMask
string
gw
string
rotarys
array of numbers (3) Current position of the rotary switches:
ulPresent
boolean
usVoltage_mv
number
ulVoltage_mv
number
inputs
array of numbers (2) Real state of digital inputs.
output
array of numbers (2) Real State of digital outputs.
146
Beschreibung
Device name
Ordering number
Firmware version
Hardware version
MAC address of the device
0 = No connection
1 = Connection with PLC
0 = Normal operation
1 = Outputs are in failsafe
IP address of the device
Subnet Mask
Default gateway
Array element 0 = x1
Array element 1 = x10
Array element 2 = x100
True, if there is a UL voltage supply
detected within valid range
US voltage supply in mV
UL voltage supply in mV (only
available for devices with UL supply)
Element 0 = 1 Byte: Port X1
Channel A to Port X4 Channel B
Element 0 = 1 Byte: Port X5
Channel A to Port X8 Channel B
Element 0 =1 Byte: Port X1
Channel A to port X4 Channel B
Element 0 = 1 Byte: Port X5
Channel A to port X8 Channel B
14 IIoT-Funktionalität
Beispiel
"0980 XSL 3912-
121-007D-00F"
"935 700 001"
"V.1.1.0.0 -
01.01.2021"
"V.1.00"
"3C B9 A6 F3 F6
05"
1
0
\[128,3\]
\[55,8\]
Handbuch EtherNet/IP