12 CIP-Objektklassen
Attribut
Name
7
Interface Type
8
Interface State
9
Admin State
10
Interface Label
11
Interface
Capability
Handbuch EtherNet/IP
Version 1.2 05/2021
Zugang
Datentyp
Get
USINT
Get
USINT
Get, Set
USINT
Get
STRING
Get
STRUCT
12.1 EtherNet/IP-Objektklassen
Beschreibung
Type of interface:
0 = Unknown interface type
1 = Internal interface
2 = Twisted-pair
3 = Optical fiber
4..255 = Reserved
State of interface:
0 = Unknown
1 = Enabled and ready to send and
receive data
2 = Disabled
3 = Testing
4..255 = Reserved
Administrative state:
0 = Reserved
1 = Enable interface
2 = Disable interface
3..255 = Reserved
Human readable identification (size
max. 64)
Interface Capability Flags (DWORD):
b0: Manual Setting Requires Reset (0)
b1: Auto-negotiate (1)
b2: Auto-MDIX (1)
b3: Manual Speed/Duplex (1)
b4..31: Reserved (0)
Speed/Duplex Array Count of
following struct (USINT, 4)
Interface Speed in Mbps (UINT,
10/100)
Interface Duplex Mode (USINT, 0/1):
0 = Half Duplex
1 = Full Duplex
2..255 = Reserved