Herunterladen Diese Seite drucken

Cisal BQT0101 Technische Produktinformation Seite 17

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
GB
REPLACEMENT OF THE CERAMIC HEADVALVE
LST0101 (ref. picture 8)
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the flow rate (6)
- Disassemble the handle (6); removing the small cap (7) and unscrewing the screw (8)
- Remove the adapter (12)
- remove the lock nut (15)
- Disassemble the ceramic headvalve (16) by unscrewing it with a 17 mm wrench.
- Mount the new ceramic headvalve; by screwing it down with a 17 mm wrench
- assemble the lock nut again (15) (see the paragraph 'Adjustment of the flow rate limiting device' ).
- Assemble the adapter (12) again.
- Rotate the rod of the ceramic headvalve clockwise up to its lock.
- Insert the handle (6) with the button turned forwards.
- Tighten the screw (8) and assemble the small cap again (7).
REPLACEMENT OF THE CERAMIC HEADVALVE
BQT0101 – BAT0101 (ref. picture 9)
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the flow rate (6).
- Remove the handle (18) by unscrewing the pin (17) with a 2 mm Allen wrench.
- Remove the handle (6) by unscrewing the screw (8)
- Remove the adapter (12).
- remove the lock nut (15)
- Remove the ceramic headvalve (16); by unscrewing it with a 17 mm wrench.
- Assemble the new ceramic headvalve; by screwing it with a 17 mm wrench.
- assemble the lock nut again (15) (see the paragraph 'Adjustment of the flow rate limiting device' ).
- Mount the adapter (12) again.
- Rotate the rod of the ceramic headvalve clockwise up to its lock.
- Insert the handle (6) with the button turned forwards.
- Tighten the screw (8) and mount the handle (18) again by tightening the pin (17) with a 2 mm Allen
wrench.
REPLACEMENT OF THE DEVIASTOP VALVE
LSD2301 – LST2301 – LSC7801 (ref. picture 10)
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the flow rate (6)
- Disassemble the handle (6); removing the small cap (7) and unscrewing the screw (8)
- Remove the adapter (12).
- disassemble the fixing ring (20) by unscrewing the pin (19) with a 2 mm. Allen wrench.
- remove the nut (21) with a 30 mm. wrench
- remove the deviastop valve (22).
- insert the new deviastop valve
- screw the nut (21) with a DYNAMOMETRIC KEY, applying a 10 Nm. tightening torque.
- for art.LSD2301 o LST2301: insert the fixing ring (20) placed as shown in picture 10/A.
- for art.LSC7801 : insert the fixing ring (20) placed as shown in picture 10/B.
by tightening the pin (19) with a 2 mm Allen wrench
- Assemble the adapter (12) again.
- Insert the handle (6) with the button turned forwards.
- Tighten the screw (8) and assemble the small cap again (7).
If over time there is a reduction of the maximum flow-rate, clean or replace the filters and
the aerator fitted on the spout. See the " Master Libby" leaflet enclosed in the packaging for
details of the maintenance of the finishings.
16