Adjustment of the flow rate limiting device.
LST0101 (ref. picture 2)
- remove the flow rate control handle (6) taking away the cap (7) and unscrewing the screw (8).
- remove the flow rate limiting device (9) and place it in one of the 7 possible positions that generate
the blockage of the rotating handle.
- Temporarily assemble the handle and check if the flow rate has been reduced by the desired quantity.
- Complete the handle's assembly, by tightening the screw (8) and inserting the cap (7).
BQT0101 – BAT0101 (ref. picture 3)
- Remove the handle (18) by unscrewing the pin (17) with a 2 mm Allen wrench.
- Remove the handle (6) by unscrewing the screw (8)
- remove the flow rate limiting device (9) and place it in one of the 7 possible positions that generate
the blockage of the rotating handle.
- temporarily assemble the handle and check if the flow rate has been reduced by the desired quantity.
- complete the assembly, by tightening the screw (8) and assemble the handle (18) again.
OPERATION
LSD2301 – LST2301 (ref. picture 4)
- The water temperature can be adjusted by the handle (5). The temperature adjustment is limited to
38°C by means of a safety device. If a higher temperature is required; press the safety button placed on
the handle itself.
- through the handle (6) you can select the desired outlet (outlet to the bath's tub : clockwise rotation;
outlet to the shower: counter-clockwise rotation) and the flow rate. There is a safety block device:
to select the outlet to the shower, press the button placed on the handle.
OPERATION
LSC7801 (ref. picture 5)
- The water temperature can be adjusted by the handle (5). The temperature adjustment is limited to
38°C by means of a safety device. If a higher temperature is required; press the safety button placed on
the handle itself.
- through the handle (6) you can select the desired outlet (outlet to the shower head : counter-clockwise
rotation; outlet to the hanspray : clockwise rotation) and the water flow. There is a safety block device:
to select the outlet to the shower. Press the button placed on the handle.
MAINTENANCE
FILTERS' CLEANING (ref. picture 1)
- Close the cold and hot water inlets.
- Empty the mixer of the water by opening the flow rate handle (6)
- Remove the mixer, unscrewing the fixing nuts (4) with a 30 mm wrench.
- Remove the gaskets with filter (3) from the fixing nuts (4).
- Clean the filters with a brush and rinse them; in case of calcareous incrustations; dip the gaskets with
filter in the product Cisal Master Libby (article ZA00800) and then rinse them.
- Insert again the gaskets with filter (3) in the fixing nuts (4).
- Assemble again the mixer by tightening the fixing nuts (4) with a 30 mm. wrench.