TROUBLESHOOTING
During recording of the RED, the buzzer sounds for 3/5 second
During recording of the RED, the buzzer emits 2 tones
The buzzer emits a tone every 3 seconds and the blinker during the gate operation
flashes 2 times followed by a pause of 3 seconds for 1 minute and one of the EDGE
PHOT LEDs is turned on red
The gate doesn't move. The buzzer emits an alternating sound and the blinker
flashes 2 times followed by a pause of 3 seconds for 1 minute and one of the EDGE
PHOT LEDs blinks green/red.
The buzzer does not sound when the batteries are removed from the strip
TECHNICAL FEATURES
- FREQUENCE
- SENSITIVITY
- OUTPUT POWER
- BATTERY FEED
- IDLE ABSORPTION
- MAX ABSORPTION
- MODULATION TYPE
- RANGE
- BATTERY(IES) LIFE
- CASE
- SIZE
- PROTECTION LEVEL
- OPERATION TEMPERATURE
ACCESSORIES
AA ALKALINE BATTERIES
4 X 1,5V - battery life with RED - 3 years.
PROBLEM
868,3 MHz
-108 dBm
<25 mW
3 x AA1,5 V (> 2,7 Ah)
25 uA
13 mA
FSK
20 m in free space without aerial
3 years (Alkaline)
4 years (Lithium)
External - Technopolimer
129x89x58 mm
IP56
From -20°C to +60°C
code ACG9519
It has been tried to record a RED with wrong DIP.
Verify that the EDGE PHOT LED that blinks on MASTER Wi-Fi corresponds to the dip
on RED to memorize
RED code is already in the memory
Replace as soon as possible the batteries of the RED as they are low
Replace the batteries of the RED as they are empty
On the MASTER Wi-Fi, verify that the EDGE PHOT DIP corresponding to the RED is
in ON position
AA LITHIO BATTERIES
2 X 1,5V - battery life with RED - 4 years (buy 2 pieces).
For extreme temperatures -40 ÷ +60°C.
19
CHECK
code ACG9509
G
B