RECORD A RED ON MASTER Wi-Fi
Use the following procedure for recording:
- Push the button PROG RX on the MASTER Wi-Fi => EDGE PHOT LED 1
flashes red for 1 minute (the time available for recording).
- Push the button PROG TX (S2) on the RED with DIP1 in ON position => on
the MASTER Wi-Fi the EDGE PHOT LED 1 flashing red turns green and a sound
from the buzzer indicates that the safety device has been recorded correctly,
immediately the EDGE PHOT LED 2 begins flashing red.
- If there are no other safety devices to be recorded, after one minute the
EDGE PHOT LED 2 will turn off or, push the button PROG. RX 4 times to end
the recording procedure => all of the EDGE PHOT LED should be off.
RECORDING OF OTHER SAFETY DEVICES
- After having recorded the first safety device, the EDGE PHOT LED 2
automatically begins flashing red for 1 minute (the time available for recording).
- Push the button PROG. TX (S2) on the RED with DIP 2 in ON position => on the
MASTER Wi-Fi the EDGE PHOT LED 2 flashing red turns green and a sound from
the buzzer indicates that the RED has been memorized correctly.
- Follow the same procedure for any other safety devices (up to a maximum of 6).
RED SYSTEM CHECK with TOUCH safety strip
After having calibrated the TOUCH strip correctly:
- Push the contact of a TOUCH strip connected to a RED (for example: RED
number 3).
- On the MASTER Wi-Fi check that the EDGE PHOT LED 3 flashes green and that
the paired LED DL2 momentarily turns off and then turns on.
ATTENTION: after receiving the first signal, other signals are ignored for 2
seconds. If there is a signal in these 2 seconds it will be from the
EDGE PHOT LED 3 which turns green.
- Repeat the LED activation check on the MASTER Wi-Fi pushing the other TOUCH
strips installed.
- Perform a final check of all of the REDs installed, activating the movement of the
automation and ensuring that upon impact with the strip the automation stops/
reverses movement.
RED ALARM SIGNAL CHECK
example: Check that by taking the battery out of RED with DIP3 in ON position,
EDGE PHOT LED 3 on the MASTER Wi-Fi blinks red/green while LED DL2
turns off, and that the buzzer emits tones for 1 minute.
Repeat the check for any other RED installed.
Note: if the battery is removed and the buzzer on the MASTER Wi-Fi does not
sound, EDGE PHOT DIP 3 is in the OFF position (go-ahead not enabled).
Turn it to ON.
WARNING STATUS (replace the batteries)
The warning status tells the user of the imminent need to replace the batteries.
When batteries power reaches 3V, RED signals to the MASTER Wi-Fi the low
battery status and it activates the BUZZER with a sound every 3 seconds for 1
minute.
The warning is renewed for 1 minute if a command is given to the door.
On the MASTER Wi-Fi, the EDGE PHOT LED corresponding to the RED with the
low batteries, turns on red.
The SPARK Wi-Fi blinker (if available) indicates the warning by emitting 2
consecutive flashes followed by a pause for 3 seconds for the duration of
the opening or closing of the door.
The system is still operational during these signals, but it is advantageous to
replace the batteries as soon as possible in order to avoid a full stop of the door
operation which happens when the batteries reach 2,7V.
ALARM STATUS (batteries completely exhausted or RED not working)
The alarm status starts when the batteries are completely empty (2,7V) or when
the device stops working.
On the MASTER Wi-Fi the LEDs DL2 and DL3 turn off and MASTER Wi-Fi blocks
the automation.
On the MASTER Wi-Fi the EDGE PHOT LED corresponding to the RED with the
low or non-functioning batteries, blinks red/green. The BUZZER emits tones for 1
minute, while the SPARK Wi-Fi blinker (if available) signals the alarm status
by emitting 2 consecutive flashes followed by a pause for 3 seconds,
notifying the user that the batteries must be replaced or RED needs to be
repaired.
The alarm is renewed for 1 minute if a command is given to the door.
PROCEDURE TO DELETE ALL RECORDED SAFETY DEVICES
To delete all the safety devices recorded in the MASTER Wi-Fi memory, just push
and hold the PROG. RX button for 10 seconds. After 10 seconds all of the LEDs
EDGE PHOT will blink red/green 6 times, indicating successful deletion.
Afterwards the EDGE PHOT LED and LEDs DL2 and DL3 will turn off.
ATTENTION: WITH LED DL2 AND DL3 OFF, AUTOMATION DOES NOT WORK.
PROCEDURE TO DELETE JUST ONE SAFETY DEVICE
In order to remove a single safety device recorded on the MASTER Wi-Fi, use the
following procedure:
- Push the PROG. RX button one or more times to select the EDGE PHOT LED,
corresponding to the safety device to delete. EDGE PHOT LED begins flashing
green
- After selecting the RED, push and hold the PROG. RX button for 10 seconds.
- After 10 seconds the EDGE PHOT LED blinks red/green 6 times, indicating
successful deletion.
ATTENTION: Place the EDGE PHOT DIP corresponding to the deleted safety
device in OFF position, then scan the LEDs EDGE PHOT pushing
the PROG. RX button 6 times.
REPLACING THE BATTERIES
The lifespan of the 1,5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program
the safeties.
- Identify the safety device with the exhausted batteries by checking the diagnostic
of the EDGE PHOT LED on the MASTER Wi-Fi.
- Use the number on the side of the EDGE PHOT LED which blinks red/green, or
that turns on red, to identify the number of the safety device with the exhausted
batteries.
- Find the RED with the numbered sticker corresponding to the number of the
EDGE PHOT LED which is in alarm status on the MASTER Wi-Fi.
- Replace the batteries, checking that the polarity is correct.
- Push PROG TX button on the RED to restart the MASTER Wi-Fi.
- The buzzer of the MASTER Wi-Fi will turn off and the LEDs DL2-DL3 (if in alarm
status) will turn on. The EDGE PHOT LED corresponding to the safety device with
the replaced batteries will turn off.
The automation is now ready to restart in complete safety.
ATTENTION: Please remember that batteries must be disposed properly according
to current Standards. In case of disposal of the safety devices, please
remember to remove the AA batteries and dispose them properly.