Adjusting the room temperature
Fig. 7-4: Example: adjusted room temperature 21 °C
7.3
Limiting temperature adjustments
The adjustment range of the rotary knob is factory-set to a minimum of +8 °C and a
maximum of +30 °C by means of restrictors. The restrictors can be adjusted to set the
minimum and the maximum adjustable temperature.
1. Turn the cam screw at the product by approximately 90° using a screwdriver.
2. The rotary knob is lifted and can be removed.
Fig. 7-5: Removing the rotary knob
Operation
90°
RoCon UFH
1. Adjust the desired tempera-
ture at the room controller.
- Without temperature
reduction: The product
controls the room tempera-
ture to the adjusted value
- With temperature reduc-
tion: The product controls
the room temperature to a
value 4 K below the
adjusted value